Safety issues to remember
• Electricity can be dangerous, use of an RCD should not be
regarded as a substitute for basic electrical safety precautions.
• Always test the RCD before use. If the test procedure is not
completed satisfactorily or an appliance continues to trip the
RCD seek professional advice and switch off the appliance.
• To clean, use a clean dry cloth only.
Do NOT use any liquid cleaners.
• A warming of the case during use is normal.
Wiring tests – important
Remove this product from circuit if carrying out tests
(as described in the IEE Wiring Regulations) for earth loop
impedance, prospective short circuit current and
insulation resistance.
Use the enclosed warning label to ensure this is carried out.
General RCD specifications
Voltage:
230V AC 50Hz
Max current:
Fully complies with the current
rating required by BS1363
Rated trip current:
30mA
RCD type:
Double pole, suitable for
2 and 3 wire applications
Breaking capacity:
250A (Earth leakage)
Through fault withstand:
1500A
Operating temperature range: -5ºC to 40ºC
Trip speed:
Less than 40msec at
150mA residual current
Fully complies with:
BS7288 & BS1363