IP66 Products covered by  

these instructions

TGVL01

 

One gang two way switch 10AX

TGVL02

 

Two gang two way switch 10AX

TGVL03

 

One gang bell push

TGVL05

 

One gang double pole switch 20A

TGV101N

 

One gang socket switched 13A

TGV201N

 

Two gang socket switched 13A

TGV104N

 

One gang RCD spur

TGV204N

 

Two gang RCD protected socket 13A  

 (passive/latching)

TGV205N

 

Two gang RCD protected socket 13A  

 (active/non-latching)

TGV103N

 

One gang switched fused spur 13A

General

Please note that all instructions are to be left with the customer 

after installation.
The Weathersafe Vision range is manufactured from tough, 

durable thermoplastic, and is intended for use in an outdoor 

environment, or one in which the protection provided by the 

Weathersafe Vision range is required.
All the products are rated IP66, for protection against water 

and dust. All Weathersafe Vision products need to be fitted 

with waterproof cable and conduit entries to maintain their  

IP rating once installed.

Summary of Contents for Weathersafe Vision TGV101N

Page 1: ...I n s t a l l a t i o n O p e r a t i n g I n s t r u c t i o n s Weathersafe Vision...

Page 2: ...t 13A active non latching TGV103N One gang switched fused spur 13A General Please note that all instructions are to be left with the customer after installation The Weathersafe Vision range is manufac...

Page 3: ...t person e g qualified electrician in accordance with these instructions and in compliance with the appropriate clauses of the current edition if the IEE wiring and building regulations Sockets should...

Page 4: ...the lowest point of the conduit The relevant cable entry knock out should be unscrewed A waterproof cable or conduit entry must then be fitted in its place If two cable entry positions are used with m...

Page 5: ...ee fig 2 Plugs may be inserted into the sockets and the socket switches turned on The lid should then be closed to maintain the IP rating taking care to ensure that the cables are aligned with the cen...

Page 6: ...blue for TGV205N button marked Reset R the status indicator should show red TEST press the red button marked Test T status indicator should show black This indicates that the RCD has been tripped and...

Page 7: ...ting the RCD any connected appliance may be switched on and used in the confidence that the user is protected from electric shock by rapid disconnection of supply If the RCD trips Turn the appliance s...

Page 8: ...s important Remove this product from circuit if carrying out tests as described in the IEE Wiring Regulations for earth loop impedance prospective short circuit current and insulation resistance Use t...

Page 9: ...t its pivot point Be sure to protect the casing under the screwdriver blade with a piece of card as shown Protect the case with card Concerning TGVL01 TGVL02 TGVL03 only If a local neutral is required...

Page 10: ...9 One of these two terminals marked earth can be used as a neutral terminal Fig 6 TGVL01 TGVL02 TGVL03 Earth terminal positions...

Page 11: ...purchase and it will be replaced free of charge For the second and third years or any difficulty in the first year telephone the helpline on 020 8450 0515 Note A proof of purchase is required in all...

Page 12: ...Limited Victory Park 400 Edgware Road London NW2 6ND Sales Office 020 8452 1112 or email csc timeguard com For a product brochure please contact For assistance with the product please contact or emai...