7.0 MAINTENANCE
7.1 ASH REMOVAL PROCEDURES
Check your chimney and chimney connector for creosote and soot buildup weekly until a safe frequency for
cleaning is established.
If accumulation is excessive, disconnect the appliance and clean both the chimney and the appliance. You
may want to call a professional chimney sweep to clean them. Both have to be cleaned at least once a year or
as often as necessary.
Remove fi bre baffl es and clean above them once a year. Replace any broken bricks.
Allow the ashes in your fi rebox to accumulate to a depth of two or three inches; they tend to burn themselves
up. When the fi re has burned down and cooled, remove any excess ashes but leave an ash bed approximately
1” (25mm) deep on the fi rebox bottom to help maintain a hot charcoal bed.
DISPOSAL OF ASHES:
Ashes should be placed in a metal container with a tight fi tting lid. The closed contain-
er of ashes should be placed on a non-combustible fl oor or ground, well away from all combustible materials,
pending fi nal disposal. If the ashes are disposed of by burial in soil or otherwise locally dispersed, they should
be retained in the closed container until all cinders have thoroughly cooled.
!
AVERTISSEMENT
TURN OFF THE POWER BEFORE SERVICING THE APPLIANCE.
APPLIANCE MAY BE HOT, DO NOT SERVICE UNTIL APPLIANCE HAS COOLED.
DO NOT USE ABRASIVE CLEANERS.
7.2 CREOSOTE FORMATION AND REMOVAL
IMPROPER DISPOSAL OF ASHES RESULT IN FIRES. DO NOT DISCARD ASHES IN CARDBOARD
BOXES, DUMP IN BACK YARDS, OR STORE IN GARAGES.
IF USING A VACUUM TO CLEAN UP ASHES, BE SURE THE ASHES ARE ENTIRELY COOLED. USING
A VACUUM TO CLEAN UP WARM ASHES COULD CAUSE A FIRE INSIDE THE VACUUM.
NEVER OPERATE YOUR APPLIANCE WITH THE GRATE COVER REMOVED.
FAILURE TO ACHIEVE A GOOD SEAL BETWEEN THE ASH OPENING, ASH PLUG OR ASH WELL
DOOR WILL RESULT IN AN OVER FIRE CONDITION THAT COULD CAUSE DAMAGE TO THE
APPLIANCE.
84.1A
When wood is burned slowly, it produces tar and other organic vapors, which combine with expelled moisture
to form creosote. The creosote vapors condense in the relatively cooler chimney fl ue of a slow-burning fi re. As
a result, creosote residue accumulates on the fl ue lining. When ignited this creosote makes an extremely hot
fi re.
The chimney connector and chimney should be inspected at least once every two months during the heating
season to determine if a creosote buildup has occurred.