O
PERATING
M
ANUAL
4. M
OUNTING
O
F
M
ACHINE
ThyssenKrupp Aufzugswerke GmbH
36
Issue 06.2004
The switch connections are connected at the terminal box (fig. 11) via
a 6-core screened cable (fig. 14) for signal processing.
The connection at the customer is made as break contact.
An evaluation of the signal of both switch conditions must be made
by the customer!
Switching current range min. 10 mA to max. 100 mA at 24 VDC.
Further details see chapter 8.3 Manufacturer's instructions.
After connecting check brake and monitoring switches for correct functioning.
Note:
an appropriate access to the brake and microswitches for the
inspection, adjustment or replacement works must be possible.