4.2
Motor connection
Observe terminal diagram at the cover of the motor connection box or
terminal diagram.
Adhere to fig. 8. Verify that the safety instructions and the respective local
building regulations are complied with.
Motor connection data of respective motor type see 3.3
Motor terminal diagram
:
for frequency-controlled motors
Temperature monitoring motor
Connect terminal connection "Th" (thermistor) and PTC tripping device (or
frequency inverter connection provided for that purpose.
Voltage applied shall not exceed 2.5 V.
Fig. 8
Fig. 9
Th
Th
Grd.
U
V
W