O
PERATING MANUAL
DAB530
M
AINTENANCE
/
SERVICE
ThyssenKrupp Aufzugswerke GmbH
Undo 2 screws on the magnet sensor
Replace magnet sensor with line and
connector,
mount in reverse order.
NB
Mount magnet sensor with the
line facing upwards.
Magnet sensor - setting the distance
When setting the magnet sensor, shut down the drive.
Loosely screw on the magnet sensor
Set the distance between gear wheel and encoder to
0.2
0.05
mm
using a distance gauge or foil (not metal).
Tighten screws on the magnet sensor with
maximum tightening torque
1 Nm
Screw on covers, plug connector onto connecting line
Check the operation of the encoder
Comply with the instructions of the magnet sensor
manufacturer
in the
Appendix
Fig. 7.8.7
Fig. 7.8.6
47