![Thunder Laser MINI-60 Unified User'S Manual Download Page 53](http://html1.mh-extra.com/html/thunder-laser/mini-60/mini-60_unified-users-manual_1113418053.webp)
USERS MANUAL MINI 60
D ONGGUAN T HUNDER L ASER E QUIPMENT C O.,LTD
S hatian To wn, S h atian Da dao, M intian
Tel :(86)769 826653
Do ngguan C i ty, G uangdong P r ovince, China
53
How to set default for “Air-Assist Control” option?
Go into the RDworks’s root directory>>open the text file of “soft”>>change the setting of
“ShowBlow”>>save the text file, like below.
2) How to adjust air volume if require?
For High volume mode,
1. Make sure machine is not at work and laser switch is off
2. Click the left green button to start the air-assist with high volume
3. Check the air volume under the laser head
4. On left flow control valve, loose the locked nut then rotate the adjusting screw to control
the air volume to mean your requirements.
5. Fix the locked nut after finished.
And for Low volume mode, you do it the same.
It will be the best if using big air compressor instead of air pump for
air-assist.