2. CONTROLS
12
flows to the loaders drive and cylinder spool
auxiliary hydraulic circuit. 3 gpm (11.4 l/m) flows
to the motor spool auxiliary hydraulic circuit. This
setting provides a travel speed of 3.5 mph (5.6
km/hr).
With the flow control knob turned fully in
(clockwise) approximately 1 gpm (3.8 l/m) flows to
the loaders drive system and 10.5 gpm (39.8 l/m)
flows to the motor spool auxiliary hydraulic circuit.
This provides a travel or "inching" speed of 0.3
mph (0.5 km/hr).
A/1 - Stationary Power Source
This mode is used to provide full hydraulic power
to the motor spool auxiliary hydraulic circuit to
power attachments such as water pumps where no
travel speed or boom and bucket operation is
required.
In this position the loaders travel speed, boom and
bucket circuits as well as the cylinder spool
auxiliary hydraulic circuits do not function.
Pump Selector Switch - Set switch to "A" position.
Combiner Switch - Set the switch to "1" position.
Flow Control Knob - The flow control knob does
not function in this mode.
In this mode the drive system receives 0 gpm (0
l/m) while the motor spool auxiliary hydraulic
circuit receives 11.5 gpm (43.5 l/m).
B/1 - High Speed Travel
This mode is used when long travel distances are
encountered. This position provides the fastest
maximum travel speed as well as increased oil flow
to the loaders boom and bucket and cylinder spool
auxiliary hydraulic circuit while providing reduced
oil flow to the motor spool auxiliary hydraulic
circuit. Attach the hydraulic powered attachment to
the cylinder spool auxiliary hydraulic circuit or
mount a bucket or other attachment and set the
controls as follows.
Pump Selector Switch - Set switch to "B" position.
Combiner Switch - Set the switch to "1" position.
Flow Control Knob - Turning clockwise will
reduce the loaders drive speed and increase the
amount of flow to the motor spool auxiliary circuit.
With the flow control knob turned fully out (counter
clockwise), approximately 11.5 gpm (43.5 l/m)
flows to the loaders drive and cylinder spool
auxiliary hydraulic circuit. 0 gpm (0 l/m) flows to
the motor spool auxiliary hydraulic circuit. This
setting provides a travel speed of 4.4 mph (7.1
km/hr).
With the flow control knob turned fully in
(clockwise) approximately 1 gpm (3.8 l/m) flows to
the loaders drive system and 10.5 gpm (39.8 l/m)
flows to the motor spool auxiliary hydraulic circuit.
This provides a travel or "inching" speed of 0.3
mph (0.5 km/hr).