6
Remove key when not in
operation.
IMPORTANT
This engine is equipped
with glow plugs. Do not
use ether or any high
energy fuels to assist
starting.
IMPORTANT
2. CONTROLS
It is necessary to become familiar with the location
and purpose of each control before operating the
Mini-Skid Loader.
1.
Pump Selector Switch: Selects either primary
or secondary circuit.
2.
Safety Interlock Pushbutton: Activates
Hydraulic flow to the Mini-Skid Loader.
3.
Speed Regulation Switch: Controls the
diverting of oil from one circuit into the other.
Toggle upwards to activate. Toggle downwards
to deactivate.
4.
Low Engine Oil Pressure Light: This light
illuminates if the engine oil pressure is low.
Stop the engine immediately and determine the
cause.
5.
Hourmeter: The hourmeter records the
number of engine operating hours and has a
total of 9999.9 hours.
6.
High Engine Coolant Temperature Light:
This light will illuminate if the coolant
temperature has exceeded recommended
levels. If this occurs, shut off the engine
immediately following proper shutdown
procedures and determine the cause.
1
2
3
4
5
6
7
8
9
2.1 INSTRUMENT PANEL
To prevent personal
injury, never add fuel to
the Mini-Skid Loader
when the engine is
running or is hot.
NO SMOKING.
WARNING
To prevent personal
injury, do not start the
engine unless you are
on the Operator’s
Platform.
WARNING
7.
High Hydraulic Oil Temperature Light: This
light will illuminate when the oil temperature
has exceeded recommended levels. Shut off the
engine immediately and determine the cause.
8.
Light Switch: Turns working light on and off.
9.
Ignition Switch: The ignition switch is a four
position switch. Clockwise from the OFF
position are the ON, and START positions.
Counter-Clockwise is the GLOW position.
Fig. 2.1
https://www.tractormanualpdf.info/