THCV242_ Rev.2.00_E
Copyright
©
2019 THine Electronics, Inc. THine Electronics, Inc.
31/53
Security E
6.5.1.2.
Video stream switch and copy/distribution
Setting of data stream handling can be configurable by 2-wire access to internal register.
Table 17.
Data stream handling setting
Table 18.
Data stream handling mode
Address
bit
R/W
Initial
0x1501
[7:5]
-
3'b000
[4:0】
R/W
5'b0000_0
R_MODE_NO
Main-Link input data stream handling mode number
5'd0,1,2,3,8,10,11 are available. Others: reserved
Register Name
Description
-
Reserved
Handling
Input
R_MODE_NO
Camera
Main-Link_0
Main-Link_1
MIPI_0
MIPI_1
5'd0
1
Disable
1
-
Cam A
-
Cam A
-
5'd1
1
Enable
2
-
Cam A
-
Cam A
Cam A
5'd2
1
Disable
1
-
-
Cam B
Cam B
-
5'd3
1
Enable
2
-
-
Cam B
Cam B
Cam B
5'd8
1(2port)
Disable
1
-
Cam A
Cam A
Cam A
-
5'd10
2
-
2
Disable
Cam A
Cam B
Cam A
Cam B
5'd11
2
-
2
Enable
Cam A
Cam B
Cam B
Cam A
Input
Output
Distribution
Output port Output sw ap