5.6 DATAFORMAT
The data are output in tabular form with fixed telegram length. Separator is at least one space
(ASCII 32). Lines are concluded with "CR LF". Decimal separator is the point. Erroneous values are
marked by one or several "?" respectively “!”. Non-configured internal channels are marked by one
or more “-“. The end of the serial (COM1 and USB) data output is identified with the End Line (not
on SD.Card, ref. to chap.
Remark:
The date and time in the data line refers to the end of the measurement.
5.6.1 MEAN
DATA
Data Line Mean Data:
Sensor
values:
Sequence as in display (ref. to chap.
47 - 56
021579/06/09
8.7333 30.0 11.1 …….. 8.09.08 8:44 CR LF
2.Sensor
line feed
1.Sensor
carriage return
Time in
Time
decimals
Date
Examples (9.1756.x0.
1
00, Sensor-Interface with 6 additionally sensors):
15.0667 57.5 329 -1.5 ???.? 0.0 ????.? 1033.2 24.4 0.0 1.0
0.0 1.1 1.2 1.0 -5.0 51.6 27.10.08 15:04
15.0833 57.5 329 -1.5 ???.? 0.0 ????.? 1033.2 24.4 0.0 1.0
0.0 1.0 1.2 0.8 -5.0 51.6 27.10.08 15:05
15.1000 57.5 329 -1.5 ???.? 0.0 ????.? 1033.2 24.6 0.0 1.0
0.0 0.9 1.1 0.7 -5.0 51.6 27.10.08 15:06
15.1167 57.5 329 -1.5 ???.? 0.0 ????.? 1033.2 24.6 0.0 1.0
0.0 1.1 1.2 1.0 -5.0 51.6 27.10.08 15:07