5.6.2 Extreme
DATA
Data Line Extreme Data:
Sensor values: Sequence as in display (ref. to chap.
48 - 56
021579/06/09
1. Sensor
11.0633 0.3 11:01 3.1 11:03 ..... 8.03.08 11:05 CR LF
line feed
carriage return
time
date
time of the maximum value
maximum value
time of the minimum value
minimum value
time in decimals
Remarks:
The time of minimum and maximum values are round up to the next minute.
Special case wind direction: The minimum value is always marked with “?”, and
the maximum value is the direction at the highest gust (maximum) of wind speed.
Examples (9.1756.x0.
1
00, Sensor-Interface SIF001 with 6 additionally sensors):
13.0000 57.5 12:51 57.6 12:51 ??? 00:01 329 12:51 -1.5 12:51 -1.4 12:51
???.? 13:19 ???.? 13:19 0.0 12:51 0.0 12:51 ????.? 15:01 ????.? 15:01
1033.0 12:51 1033.5 12:51 24.5 13:00 24.7 12:51 0.0 12:51 0.0 12:51
1.0 12:51 1.0 12:51 0.0 12:51 0.8 12:55 0.0 12:56 2.0
12:51 0.2 12:56 2.1 12:52 0.0 12:52 2.3 12:52 -5.0 12:51 -5.0
12:51 51.6 12:51 51.6 12:51 27.10.08 13:00
13.1667 57.5 13:01 57.6 13:01 ??? 00:01 329 13:01 -1.5 13:01 -1.4 13:01
???.? 13:19 ???.? 13:19 0.0 13:01 0.0 13:01 ????.? 15:01 ????.? 15:01
1033.0 13:01 1033.5 13:01 24.3 13:09 24.5 13:01 0.0 13:01 0.0 13:01
1.0 13:01 1.0 13:01 0.0 13:01 0.3 13:04 0.0 13:02 2.1
13:08 0.0 13:07 2.2 13:09 0.0 13:02 2.0 13:10 -5.0 13:01 -5.0
13:01 51.6 13:01 51.6 13:01 27.10.08 13:10
5.6.3 END
LINE
End line is only output by the serial interfaces COM1 and USB.
END OF DATA Station: THIES DLx(Met) V1.01a USB: 0
USB state (on/off)
Software-Version “V1.01a”
Instrument Type “DLx(Met)”
Station name „THIES
“ e.g.