Command SM
<id>SM<parameter><CR> Power saving mode
Access:
reading / writing
Description:
The command enables reading and setting the power saving
mode.
Parameter type:
unsigned integer
Parameter:
0: all modules active
1: µC and interfaces disabled
(frequency output active, when FO = 7)
After activation of power-saving mode the sensor cannot be op-
erated via the serial interface after approx. 30sec. After a restart
the interface is active for 30 sec.
Parameter HT0 should be set in the power-saving mode.
2: reserved
Type return value:
unsigned integer
Return value:
see parameter
Value range:
0...2
Initial value:
0
Note:
After resetting parameter 2 ("FO2") to parameter 0 ("FO0"), the encoder must
be restarted! A restart can be carried out with the "RS2" command (pass-
word level "User" / KY234).