7.2.3 Plug and Cable Mounting
Coupling socket, Type: Binder, Serial 423, EMC with cable clamp
Cable connection:
with
cable shield
1. Stringing parts on cable acc. to plan given
above.
2. Stripping cable sheath 20mm
Cutting uncovered shield 15mm
Stripping wire 5mm.
Cable mounting 1
Putting shrink hose or insolating tape be-
tween wire and shield.
Cable mounting 2
If cable diameter permits, put the shield
backward on the cable sheath.
3. Soldering wire to the insert, positioning
shield in cable clamp.
4. Screwing-on cable clamp.
5. Assembling remaining parts acc. to upper
plan.
6. Tightening pull-relief of cable by screw-
wrench (SW16 und 17).
Cable mounting 1
View X
wire
Cable clamp
shield
Cable shield
Cable mounting 2
View X
Cable connection:
without
cable shield
1. Stringing parts on cable acc. to plan given
above.
2. Stripping cable sheath 20mm
3. Cutting uncovered shield 20mm
4. Stripping wire 5mm.
5. Soldering wire to the insert.
6. Positioning shield in cable clamp.
7. Screwing-on cable clamp.
8. Assembling remaining parts acc. to upper
plan.
9. Tightening pull-relief of cable by screw-
wrench (SW16 und 17).
Cable clamp
Cable sheath
Wire