![THERMOSTAHL ENERDENSE Installation And Service Manual Download Page 7](http://html1.mh-extra.com/html/thermostahl/enerdense/enerdense_installation-and-service-manual_1106265007.webp)
BOILER MOUNTING
7
2.5.
Fuel
The ENDS is designed for function with the following fuels:
1.
Natural Gas, according to DIN 4756 and 4788, with lower calorific power 10,0 kWh/Nm
3
.
The delivery conditions of natural gas to the burner are stabilized by the Norm for natural
gas I 6-98, for gas with low pressure (p=50mbar)
2.
Light oil fuel EL, according to DIN 4755 and 4787, with a viscosity of 4, 5 cSt at 20
o
C and
lower calorific power 11,5 kWh/kg.
3.
Light oil fuel with lower calorific power 11,2 kWh/kg.
If you wish to use an alternative fuel, please contact the manufacturer.
When liquid fuel is used, pay attention at the following:
•
When filling the fuel tank, avoid any water or dust entering together with the fuel in the
tank.
•
When the room temperature of the location where the boiler is mounted is lower than
0
o
C, it is recommended the use of a pre-heater.
3.
BOILER MOUNTING
3.1.
Transportation and delivery
The boiler is delivered complete with the metal covers, well packaged. The loading and
unloading of the boiler must be performed with a forklift or a crane. A special hook is provided
on the upper part of the boiler for lifting for models ENDS 180 upwards.
The boiler is heavy. Do not try to lift by hands or other unsuitable equipment.
Danger of injury! Perform all moves with extreme attention and care.
Remove the boiler packaging with attention.
Keep the packaging material away from
children since it can be dangerous.
After having unpacked everything, make sure that the
appliance is intact and undamaged. In case of doubt do not use the appliance and inform the
supplier.
The ENDS boiler is delivered with the following equipment already fitted and mounted:
▪
Boiler steel body
▪
Insulation mounted on the boiler body and tightened with plastic tapes
▪
Metal covers mounted on the boiler body
▪
Turbinators positioned inside the fire tubes
The following accessories are positioned inside the boiler body. Remove them carefully by
opening the middle door.
▪
Cleaning tools
▪
Control panel (optional)
In the documentation folder you will find:
▪
Technical manual
▪