pg. XXXVI
6
Morsetto 2 Accumulo
DEVIATRICE
( OPTIONAL )
VALVOLA
CIRCOLATORE
AGGIUNTIVO
CIRCOLATORE
MOTORE CARICAMENTO
RESISTENZA
PELLETS
Cronoterm. modem ( 3 - 6 )
Termostato ambiente ( 2 - 6 )
3
2
1
( OPTIONAL )
1 2 3
FLUSSOSTATO
2
1
3
5
4
6
2
5
6
7
3
4
9
1
10
8
7
1
1
2 2
Fu
sib
ile
3,1
5 A
TERMOSTATO SICUR.
RIARMO 100°C
MOTORE PULIZIA
BRUCIATORE
ASPIRATORE
FUMI
22
0-
24
0V
50
H
z
Fusibile 3,15
3
5
4
2
1
1
3
2
Fusibile 3,15
M
or
se
tt
o
1
Ac
cu
m
ul
o
Pressostato lato fumi ( 1 - 4 )
Termostato 42°C ( 3 - 6 )
Termocoppia
2
1 2 3
1
4 5 6
LA
TO
A
CQ
UA
1
3
2
PR
ES
SO
ST
AT
O
Fu
sib
ile
1A
11
11
11
11
11
INFORMA
INFORMA
INFORMA
INFORMA
INFORMATION FOR
TION FOR
TION FOR
TION FOR
TION FOR THE SKILLED
THE SKILLED
THE SKILLED
THE SKILLED
THE SKILLED TECHNICIAN
TECHNICIAN
TECHNICIAN
TECHNICIAN
TECHNICIAN
11.1
Main components and their operation
SMOKE PRESSURE SWITCH
This is a safety switch that stops the screw feeder motor whenever necessary. The main cause for the pressure switch tripping is a blocked
flue outlet or smoke exhaust pipe. Note that it is strictly forbidden to apply any kind of mesh screen to the end of the pipe. When the holes of the
mesh clog up they create a plug that trips the pressure switch which stops the pellet feeder.
SCREW FEEDER MOTOR
This motor is powered at regular on/off intervals controlled by a microprocessor. The operation of this motor is affected when:
-
The motor's thermal cutout trips.
-
The pressure switch trips due to blocked smoke exhaust.
-
Pellets finished.
-
Intentional shut down of the heater / boiler.
-Safety thermostat with manual reset trips.
SMOKE SUCTION UNIT
This is activated when the start up signal is given. In the first two minutes it «washes» the smoke discharge tube, that is, it functions at maximum
working rate. Once this time has elapsed it self-adjusts to the optimal speed. The exhaust continues to operate for approximately one hour from
the time the heater / boiler is switched off to allow for the evacuation of all the smoke and for safety purposes. It stops about half an hour after
the thermostat at 42°C opens.
10
10
10
10
10
ELECTRICAL WIRING
ELECTRICAL WIRING
ELECTRICAL WIRING
ELECTRICAL WIRING
ELECTRICAL WIRING
K E Y
Fuse 3.15 A
Smoke suction unit
Burner cleaning
motor
Resettable safety
thermostat 100°C
Pellet loading motor
Heater
Additional
ricirculating pump
Circulating pump
Diverting valve
(optional)
Terminal 1/2: puffer
Flow switch (optional)
Room them.
thermostat (2-6)
Chronotherm. modem
(3-6)
Smoke side pressure
switch (1-4)
Thermostat 42°C (3-
6)
Thermocouple
Water side pressure
switch
LEGENDA
Fusibile 3,15 A
Aspiratore fumi
Motore pulizia
bruciatore
Termostato sicur
riarmo 100°C
Motore caricamento
pellets
Resistenza
Circolatore aggiuntivo
Circolatore
Valvola deviatrice
(optional)
Morsetto 1/2:
accumulo
Flussostato (optional)
Termostato ambiente
(2-6)
Cronoterm. modem
(3-6)
Pressostato lato fumi
(1-4)
Termostato 42°C (3-6)
Termocoppia
Pressostato lato
acqua