thermopatch.com
18
11. Loosen the clamp screw and move the transfer sensor towards the leading edge of the
transfer image closest to the sealing iron. When the edge of the image is detected by the
transfer sensor, an asterisk ( * ) will appear on the display next to the feed length. When
you see the asterisk ( * ), on the display, tighten the clamp screw. Test the machine. The
transfer image should be centered on the sealing platen. If the image is moving after each
cycle, re-adjust the position of the transfer sensor. If the image is not centered, repeat the
setup procedure.
Ribbon Tape Setup Feed Adjustment
The first step is to adjust the feed. This feed value advances the tape after printing to the
amount of the entered value, to set up for the next print. Using the control box, the user
adjusts and controls the distance that the machine feeds.
Caution: tape tension may cause less feed length than what the display indicates. (See page
24) for adjusting tape feed length. (See page 22, step 3) for adjusting tape tension.
The distance between the left and right edges of the plate image determines the value for
the amount of feed. Measure this distance and add .2 to .4 inches (5.1 mm to 10.2 mm) to
it; this will give you your feed length.
The feed length on the controller box needs to be changed to the measurement taken. We
will use 5.2 inches (132 mm) as an example of a measurement.