16
6.2 DP2000T TRANSFER SETUP
1. Select the transfer for use and measure the distance from the leading edge of one image
to the leading edge of the next transfer as shown.
A special platen is required if this measurement is less than 2-1/2 inches ( 64 mm )
2. Install the transfers onto the machine.
3. Use the JOG button to feed the transfer image until the image is in the center of the
sealing platen.
4. Press the MENU button.
5. Press the ENTER button until the display reads “ SET FEED LENGTH: “.
6. Subtract 2 tenths of an inch, (5 mm) from the transfer measurement in step 1 and
use the UP or DOWN ARROW button to enter this number into the machine. Example –
The transfer measures 3 inches, (76 mm) from leading edge to leading edge. Subtract 2
tenths of an inch, (5 mm) from 3 inches. The number entered into the machine should be
2.8 inches, (71 mm).