9
APPLICATION
Electric vehicle recovery time
Following a power cut to the electric vehicle supply equipment (EVSE), a
15 minutes delay is initiated to monitor the total consumption of the elec-
trical system. Power to the vehicle will then be restored if the total load
consumption is lower than 80% of the main circuit breaker rating.
Electric vehicle charging time
It is recommended to schedule the charging vehicle program during
hours of low electrical consumption to minimize interruptions to the
electric charging station.
MAINTENANCE
Do not use any cleaning solvents to clean the DCC.
LIGHTS CODE
Green
The charging station is energized.
Green
The charging station is energized. The total
load exceeds 80%. If the loads exceed 80%
for a predetermined period, the charging
station will be de-energized.
Yellow
The charging station is not energized. The
total loads exceed 80%. The resumption
time will start when the total load is lower
than 80%.
Yellow
The charging station is not energized.
The total load is lower than 80% and
the recovery time is in progress. Each
flash mean two (2) minutes before the
resumption of power to the charging station.
(ex: 3 flashes = 6 minutes before power to
the charging station). During that period,
if the total load exceeds 80%, the recovery
time will restart from the beginning.
Red
Malfunction:
1) Check all connections and voltage.
2) Check the DIP switch configuration
settings.
3) Check if the current transformers (CT)
are properly connected and interlocked.
4) Check if the connection for the current
transformers are properly connected to the
PCB electronics.
5) If the problem persists, send pictures of
the installation at [email protected]
and then call 1 (833) 717-1355.
OFF
No power. Check the power source.