5
CHARACTERISTICS
Conditions for application
The DCC-9 is an Energy Management System specially designed to
allow the connection of an EV Charger to be connected to a power
source without affecting load calculation.
Installations types
Group installation, Wall installation, Ceiling installation
Main Power Supply (CB)
The DCC – Charge controller for electric vehicles can be powered by a
240/208V AC single phase source. The following options are offered by
each DCC model:
Models
Breaker
Main power supply
EV charger
60A
70A
80A
90A
100A 125A
DCC-9-30A
30A
DCC-9-40A
40A
DCC-9-50A
50A
DCC-9-60A
60A
Voltage and wiring
240/208V AC single phase:
L1, L2, Neutral, Ground.
Terminals size
up to 2/0
(CU/AL)
Frequency
50 to 60 Hz
Operation temperature
-22°F to 113°F (-30°C to 45°C)
Dimensions
*
(H" x W" x D")
Total weight
*
12" x 12" x 7.5"
17 lb (7,71 kg)
NEMA 3R enclosure
14" x 13" x 8"
18 lb (8,16 kg)
*Approximative and can change without notice.
V1
Secondary Load Supply (EVC)
The DCC – Charge controller for electric vehicles will provide power to
a charging station through a 30A, 40A, 50A or 60A 240/208V AC circuit
breaker, L1, L2 and ground. The DCC is equipped with a Square D cir-
cuit breaker (QUO230, QUO240, QUO250 or QUO260).
Trip Percentage (TP)
The DCC - Charge controller for electric vehicles is factory set to turn
off the charging station if the total consumption of a service exceeds
80%. For other configurations, please contact the factory.
Power outage
In the event of a power outage, the DCC – Charge controller for elec-
tric vehicles automatically restore the power supply to the vehicle
charging station when power returns.
Recovery time (RT)
Following a power cut to the electric vehicle supply equipment (EVSE),
a 15 minutes delay is initiated to monitor the total consumption of the
electrical power system. Power to the vehicle will then be restored if
the total load consumption is lower than 80% of the main circuit brea-
ker rating during a period exceeding the 15 minutes’ recovery time.
TYPICAL INSTALLATION
NOTES
For outdoor installation, use our NEMA 3R enclosure
(DCC-9-XXA-3R).
for HOMES