background image

4

SAFETY INFORMATION

This document describes important safety instructions which must be 
followed during installation, maintenance and application of the DCC – 
Charge controller for electric vehicles.

Warning

Read all instructions prior using this pro-
duct.
Always disconnect the DCC – Charge 
controller for electric vehicles power sup-
ply before any works.
Use only the DCC – Charge controller for 
electric vehicles by following the technical 
specifications indicated in this installation 
manual.
Do not install the DCC – Charge controller 
for electric vehicles nearby inflammable 
materials, explosives or fuels, chemical 
products and vapors.
Never spray the DCC – Charge controller 
for electric vehicles with water or any other 
liquids.
Stop using the DCC – Charge controller for 
electric vehicles immediately if defective, 
cracked, broken or damaged.
Never try to modify, repair or dismantle the 
DCC – Charge controller for electric vehi-
cles. Please contact the manufacturer for 
any malfunction.
Never insert a sharp object inside the DCC 
– Charge controller for electric vehicles at 
the risk of causing damages to the com-
ponents. 
Any improper use of the DCC – Charge 
controller for electric vehicles could result 
in serious injuries which may cause death. 
For a vertical installation on a wall, refer to 
the information’s on the enclosure for the 
choice of mounting position. 

Precautions

Any improper use of the DCC – Charge 
controller for electric vehicles can cause 
damages and premature wear of the com-

ponents, which voids the warranty.
Never use the DCC – Charge controller for 
electric vehicles above or below the tem-
perature range of -22 °F to 113 °F (-30 °C 
to 45 °C).
Only store the DCC – Charge controller for 
electric vehicles above or below the tem-
perature range of -4 °F to 158 °F (-20 °C 
to 70 °C).
The installation of the DCC – Charge 
controller for electric vehicles must be 
done in accordance with the latest electri-
cal code requirements.

Notes

It is recommended to schedule the char-
ging of the vehicle during hours of low 
electrical consumption to minimize inter-
ruptions to the electric charging station.
Always check that the DCC – Charge 
controller for electric vehicles is adequa-
tely fixed to the wall or ceiling or in a loca-
tion to avoid any damages. 
It is the installer’s responsibility to make 
sure that the electric power source is 
adequate for the use of the DCC – Charge 
controller for electric vehicles.
Do not use any cleaning solvents to clean 
the DCC – Charge controller for electric 
vehicles. 

Limited warranty

1 - 

THERMOLEC LTÉE.

 warrants the inte-

grated controls against any defects for a 
period of one year from the shipping date. 
The warranty is limited to the equipment 
and components supplier by 

THERMOLEC 

LTÉE.

2 – In case of incorrect installation, inap-
propriate use or repairs done by unautho-

rized personnel by 

THERMOLEC LTÉE.

, the 

warranty will be automatically void. 
3 - 

THERMOLEC LTÉE. 

undertakes to re-

pair or replace, at site or at the manufac-
turing location, at his option, the defective 
material only after an evaluation made by 
its representative. 
4 - 

THERMOLEC LTÉE.

 will not be held 

liable for damages or delays and will not be 
required to pay transport cost of the charge 
controller said to be defective. 
5 - 

THERMOLEC LTÉE.

 shall not be liable 

for any indirect damages or delays caused 
by faulty workmanship or materials. 
No indemnity will be paid for repairs, repla-
cements or modifications without a prior 

written consent supplied by 

THERMOLEC 

LTÉE.

 

6 – Any control device or accessory sup-
plied with the DCC – Charge controller for 
electric vehicles to be installed or connec-
ted remotely from the charge controller will 
be guaranteed by the manufacturer only 
under the special conditions mentioned in 
paragraph 5. 
7 – The components supplied for repairs 
are guaranteed for the remaining of the 
warranty on the original product or 90 days. 
The longest period will prevail.
8 – All repairs made at the 

THERMOLEC 

LTÉE.

 plant are guaranteed for 30 days 

from the date of repairs.

SPECIFICATIONS

The DCC – Charge controller for electric vehicles is a safety device 
with programmable controller that can protect an electrical distribu-
tion circuit in relation with its main breaker. It will prevent overloading 
the electrical distribution circuit by turning off momentarily the power 
to the charging station when the demand exceeds 80% of the main 
breaker rating.

Models

Breaker

Main power supply

EV charger

60A

70A

80A

90A

100A 125A

DCC-9-30A

30A

DCC-9-40A

40A

DCC-9-50A

50A

DCC-9-60A

60A

Voltage and wiring

240/208V AC single phase:
L1, L2, Neutral, Ground.

Terminals size

up to 2/0 

(CU/AL)

Frequency

50 to 60 Hz

Operation temperature

-22°F to 113°F (-30°C to 45°C)

Dimensions

*

 

(H" x W" x D")

Total weight

*

12" x 12" x 7.5"

17 lb (7,71 kg)

NEMA 3R enclosure

14" x 13" x 8"

18 lb (8,16 kg)

*Approximative and can change without notice.

V1

Summary of Contents for DCC-9 Series

Page 1: ...240 208V Single Phase 60A 70A 80A 90A 100A 125A ALIMENTATION PRINCIPALE 120 240 208V Monophas 60A 70A 80A 90A 100A 125A APPROVED MARKET North America MARCH AGR Am rique du Nord MODELS MOD LES DCC 9 3...

Page 2: ...2...

Page 3: ...licensors Additional information s are available on request The following logos are trade names or trademarks of THERMOLEC LTE E RECHARGE V HICULE LECTRIQUE in the United States and in Canada The DCC...

Page 4: ...ric power source is adequate for the use of the DCC Charge controller for electric vehicles Do not use any cleaning solvents to clean the DCC Charge controller for electric vehicles Limited warranty 1...

Page 5: ...for electric vehicles will provide power to a charging station through a 30A 40A 50A or 60A 240 208V AC circuit breaker L1 L2 and ground The DCC is equipped with a Square D cir cuit breaker QUO230 QUO...

Page 6: ...proper ins tallation Ceiling installation The installation may be done in any direction WARNING Warranty automatically void if the DCC is installed incorrectly STEP 3 INSTALLATION Ceiling installation...

Page 7: ...T Suivre les codes lectriques nationaux et locaux ainsi que les instructions contenues dans l appareil IMPORTANT Wire in accordance with local and National Electrical codes Read instructions carefully...

Page 8: ...240 208V Orange STEP 6 START UP DCC power supply 1 Supply electrical power to the DCC 2 Wait ten 10 seconds 3 Check if the contactor is switched on 4 Check the pilot light GREEN at all time compliant...

Page 9: ...rging station will be de energized Yellow The charging station is not energized The total loads exceed 80 The resumption time will start when the total load is lower than 80 Yellow The charging statio...

Page 10: ...dants de licence Ce manuel d installation ne peut pas tre modifi reproduit ou copi en tout ou en partie sans l autorisation crite pr alable de THERMOLEC LTE E RECHARGE V HICULE LECTRIQUE et ses conc...

Page 11: ...s assurer que la source d alimentation lectrique soit suffisante pour permettre l utilisation d un ou de plusieurs DCC Contr leur de charge pour v hicules lectriques Ne pas utiliser de solvants de net...

Page 12: ...riques peut per mettre l alimentation d une borne de recharge avec un disjoncteur de 30A 40A 50A ou 60A 240 208V CA L1 L2 et avec mise la terre Le DCC est muni par d faut d un disjoncteur Square D QUO...

Page 13: ...vous aux indications sur le boitier afin d assurer que l orientation de l installation soit conforme Installation au plafond L installation peut tre faite dans toutes les orientations ATTENTION Garant...

Page 14: ...208V Orange T 24V 240V 208V COM TRANSFORMER TRANSFORMATEUR 50VA 240 208V Orange TAPE 6 MISE EN MARCHE Alimentation du DCC 1 Alimenter le DCC en lectricit 2 Attendre dix secondes 3 V rifier si le conta...

Page 15: ...NT Suivre les codes lectriques nationaux et locaux ainsi que les instructions contenues dans l appareil IMPORTANT Wire in accordance with local and National Electrical codes Read instructions carefull...

Page 16: ...IP switch 3 V rifier si les transformateurs de courant CT sont bien connect s et bien enclench s 4 V rifier la connexion des transformateurs de courant aux terminaux de la carte lec tronique et la pol...

Reviews: