In the case that function
STAND BY
is not activated (
OFF
), and that connection for
the room thermostat is not overbridged, boiler will always work in power 1 no matter
which power is set.
In the case that function
STAND BY
is not activated (
OFF
), and connection for room
thermostat is overbridged (set in the factory) boiler will work in the power chosen by
the user, and when desired temperature is reached will go into modulation mode.
Boiler will shut down only if the temperature in the boiler is 80 degrees C, and will
start again when temperature drops down below desired temperature.
4.3.4.2
STAND BY mode with room thermostat connected
A.
FUNCTION STAND-BY SET ON– room thermostat shuts down boiler
When room thermostat sends signal that desired temperature in the room is reached
(contact is open/temperature is reached) boiler will shut down after 2 minute (factory
settings- in the case that temperature in the room changes all to prevent constant
turning on and off of the boiler) on display is written
tOFF-WAITING REQUEST.
When room thermostat gives signal that room temperature is low (contact closed/
temperature needs to be reached) boiler will start ignition and on display is written
tON.
Remark:
Boiler functioning primarily depends on temperature of the water inside of
boiler and factory settings inserted. If boiler is in state of
WAITING COOLING
(water
temperature is reached), eventual request of the thermometer will be ignored.
B.
FUNCTION STAND-BY SET OFF – room thermostat gives signal to the
boiler to work in POWER 1
In the case that function
STAND BY
is not activated (
OFF
) boiler will work in power
chosen by the user and when desired temperature is reached boiler will modulate (will
not shut down but working power will change to lowest).
Boiler will shut down only if temperature of the water in the system is 80 degrees C,
and on display is written
WAITING COOLING
. Boiler will start again when
temperature in the system drops down below set temperature.
Option Buzzer
B
UZZER
is used in the case that user want to hear sound signal from the boiler
in the case of activated alarm (set
ON
), or without sound signal (set
OFF
).
Option
BUZZER
is activated by pressing of button
SET
, and after that with
buttons
5
or
6
we choose item
MENU 05- OPTION BUZZER.
By pressing of the button
SET
choice
ON
or
OFF
is opened (with buttons
1 or 2
we are selecting option and confirmation is done by pressing
SET
).
Summary of Contents for Pelling 100
Page 2: ...2...
Page 17: ...PELLING 17...
Page 18: ...PELLING 18 Clock adjustments Clock adjustments can be done on following way...
Page 20: ...PELLING 20 Flowchart 2 Flowchart 3 Flowchart 4...
Page 37: ...PELLING 37 8 Connection options 8 1 Hydraulic schemes for connection...
Page 38: ...PELLING 38...
Page 39: ...PELLING 39...
Page 40: ...PELLING 40...
Page 43: ...PELLING 43...
Page 47: ...PELLING 47 12 EU Label...
Page 48: ...PELLING 48...
Page 49: ...PELLING 49...