PELLING
26
5.4
Adjustment of water temperature in
boiler
Adjustment of water temperature in the boiler is done by pressing button 1 or 2 (*1).
Temperature can be set in range from 50°C to 80°C (*2). These are factory settings
and it is not possible to set lower or higher temperature then above mentioned.
5.5
Modulation
When water temperature in boiler is near to set value regulation begins to modulate
its work and changes power to lowest. Modulation starts 4 °C below set temperature.
EXAMPLE: We have adjusted water temperature on 73°C and power 5, regulation will
work in power 4 when temperature is 70°C, on 71°C boiler will work in power 3, on
72°C power is 2 and when 73°C is reached then boiler is working in power 1.
MODULATION
is displayed.
If temperature rises above set temperature by 2°C, boiler will be shut down
automatically and on display will be written
WAIT COOLING
.
When temperature in the boiler decreases for 2 °C below set temp. regulation will start
process of ignition again.