Operation
Mode/Fault Alarm Setup
Thermo Scientific
DensityPRO User Manual
4-9
System Tab
To access the information on the Mode/Fault Alarm Setup System tab using only the
remote transmitter keypad, see
Figure 4-6.
Mode/Fault Alarm Setup, System Tab
The following alarms are available for configuration on the System tab of the
Mode/Fault Alarm screen.
1.
Hold Mode Active Alarm
a.
The alarm is triggered when any of the items listed below are in hold mode.
i.
Current output A or B or C.
ii.
Relay A or B.
iii.
Measurements 1, 2, 3 or 4.
b.
The alarm clears when all of the items listed above are out of hold mode.
2.
RBP Communication Failed Alarm:
a.
The alarm is triggered when RBP communication errors occurs.
b.
The alarm clears when RBP communication errors are removed.
3.
Fieldbus Communication Failed Alarm
a.
This alarm has not yet been implemented, but will be available in future
releases.
4.
System Fault Alarm
a.
The alarm is triggered when any of the following actions occur.
i.
Diagnostic error:
ii.
An Input Scan Error occurs and the gauge has a problem reading any of
the following devices:
Analog inputs