Product Overview
Basic System
1-2 AutoPILOT PRO Flow Computer User Guide
Thermo Fisher Scientific
The main board contains the primary logic functions of the flow computer
and has the following features:
Interface to the display
Flash memory for program storage and data storage, 2 M x 16
SRAM memory for data storage, 1 M x 16, battery backed
Real-time clock (RTC)
Lithium backup battery; voltage monitor for the RTC and SRAM
circuits allows for data and configuration retention in the event of
power failure
Local I/O consisting of:
- Three analog inputs
- One 100-ohm Pt RTD input
- Two discrete outputs
- Two discrete inputs
- Two pulse inputs
- One local Honeywell smart transducer connection
- One local serial communication port
- One RS232/RS485 host serial communication port
- Connection for AutoMITTER safety interface board (SIB) for
communication with multiple remote transducers controlled by a
Thermo Scientific AutoMITTER PRO transmitter
- Connection for optional modular expansion boards (MEBs)
- Two +12 V power supply outputs for wireless communication
devices: One for wireless radio and one for a Bluetooth
wireless
module (future)
- One Ethernet communication port with ESD protection for
connection to the Internet
- One USB port (future)
Power consumption of 1 W (3.6 W with full connections)
Main Board