Unit Description (Rev. 1/99)
10
UNIT FEATURES
•
Digital Thermometer
•
Electronic Thermostat
•
Defrost Timer
•
Hot Gas Defrost
•
Defrost Termination Switch
•
Liquid Injection System
•
Manual Defrost Switch
•
Receiver Tank with Outlet Service Valve
•
Suction Pressure Regulator
•
Oil Separator
•
Compressor Powered by Truck Engine
•
Three-way Valve Refrigeration System
•
Accumulator Tank
•
Standby Compressor (Model 20 only)
•
Refrigerant Flow Controlled by Discharge Check Valve
(Model 20 only)
PROTECTION FEATURES
•
Control Circuit Breaker(s):
40 amp auto reset in 12 Vdc system
•
Refrigerant High Pressure Cutout
•
Refrigerant Low Pressure Cutout
•
Refrigerant High Pressure Relief Valve
•
Power Cord Warning Light (in Optional Cab Control
Box for Model 20 only)
•
Overload Relay Protection for Electric Standby Motor
(Model 20 only)
•
Transformer Fuses (Model 20 only)
OPTIONAL FEATURES
•
Cab Control Box
•
Refrigerant R-134a
•
Electric Motors (Model 20 only)
230 Volt/1 Phase/60 Hz
220 Volt/1 Phase/50 Hz
230 Volt/3 Phase/60 Hz
460 Volt/3 Phase/60 Hz
380 Volt/3 Phase/50Hz
415 Volt/3 Phase/50 Hz
•
Heat, Truck Engine (Model 10)
•
Heat, Truck Engine and Electric Standby Heater Strips
(Model 20)
•
Paint, Special Color
SERIAL NUMBER LOCATIONS
Condenser: Roadside, top corner.
Evaporator: Roadside panel.
Compressor: Nameplate on compressor body.
Standby Motor: Nameplate on motor.
Summary of Contents for 914 724
Page 4: ......
Page 8: ......
Page 14: ...4...
Page 16: ...6...
Page 32: ...22...
Page 38: ...28...
Page 98: ...88...
Page 107: ...97 Model 10 and 20 Schematic Diagram...
Page 108: ...98 Model 10 Wiring Diagram...
Page 109: ...99 Model 20 Wiring Diagram...
Page 110: ...100 Model 20 Single Phase with Heat Option Schematic Diagram...