Specifications (Rev. 1/99)
2
R-404A REFRIGERATION SYSTEM (continued)
Condenser Pressure Fan Switch:Opens
130 ± 10 psi (896 ± 69 kPa)
Closes
180 ± 10 psi (1241 ± 69 kPa)
Suction Pressure Regulator Setting
18 psi (124 kPa)
Defrost Timer: Intuition Interval
4 hours
Termination Interval
45 minutes
ELECTRICAL SYSTEM
Circuit Breaker Ratings
12 Vdc 40 amp manual reset
24 Vdc 25 amp manual reset
Condenser and Evaporator Fan Motors
Voltage
Horsepower
Power Rating in
Kilowatts
rpm
Full Load Current
12 Vdc
0.17
0.12
1850 to 2250
8.0 to 14.5 amps
24 Vdc
0.1
0.12
1850 to 2250
4.2 to 7.8 amps
Pilot Solenoid and Liquid Injection Solenoid Coils
Voltage
Current
Resistance
12 Vdc
0.6 to 0.8 amps
15 to 19 ohms
24 Vdc
0.3 to 0.4 amps
62 to 72 ohms
Electric Standby Compressor Motors
Voltage
Phase
Frequency
Horsepower
Power Rating
in Kilowatts
Full Load
rpm
Full Load
Current
230 Vac
1
60 Hz
3
2.2
1755
12.4 amps
220 Vac
1
50 Hz
2.5
1.9
1470
11.0 amps
230 Vac*
3
60 Hz
3
2.2
1750
9.8 amps
460 Vac*
3
60 Hz
3
2.2
1750
4.9 amps
380 Vac*
3
50 Hz
2.5
1.9
1420
5.0 amps
380 Vac
3
50 Hz
3
2.2
1420
5.2 amps
415 Vac
3
50 Hz
3
2.2
1420
4.7 amps
*Motor can be wired for all three voltages.
Summary of Contents for 914 724
Page 4: ......
Page 8: ......
Page 14: ...4...
Page 16: ...6...
Page 32: ...22...
Page 38: ...28...
Page 98: ...88...
Page 107: ...97 Model 10 and 20 Schematic Diagram...
Page 108: ...98 Model 10 Wiring Diagram...
Page 109: ...99 Model 20 Wiring Diagram...
Page 110: ...100 Model 20 Single Phase with Heat Option Schematic Diagram...