The size of flue canal and chimney should not be less than the size of the boiler flue gas outlet
connection. For the total height and the minimum internal diameter of the chimney, following
diagram should be referred in respect with boiler output power, if otherwise stated in mandatory
regulations.
5.7 Electrical installation
The boiler is fed with 230 V. A regulator must be used in installations where the power supply is
below 205 V or above 230 V.
WARNING
All electrical installations must be carried out by authorized persons in accordance
with mandatory regulations and codes of practice. Only qualified personnel may
open the control panel on the boiler. Any interference with the wiring in the
control panel will invalidate the warranty.
Connecting the power cord
Control panel should be connected to a wall plug with an efficient ground
system, which is placed not far more than 50 cm. to boiler with a circuit
breaker which has at least 3 mm gap between contacts. Use the power cord
supplied with the boiler.