Cortina S manuel Ver.01
19
7.1 Supply Voltage Lack Management
In case of power failure, the system saves the most important functioning data. When the control
board is supplied again, the system evaluates the saved data and if the Burner were ON in the
phases Ignition, Normal, Modulation, Standby, the system goes in Recover Ignition.
In case of functioning state of OFF or Block, the system goes back to the previous state.
7.2 START-UP
Loading the pellets
Open the fuel loading door, and fill the container with pellets. Do not put any other fuels than
specified wood pellets, or any other material. Then close fuel loading door. Observe the fuel level
in the container each day through the inspection window at the right hand side of boiler.
At the first loading the feed screw may be empty. So use the manual pellet loading function (look:
“usermenu-settings”) to supply some pellets to the feed screw.
Switch ON the boiler
Check the boiler to be in “OFF” position (fixed led L3).
Switch ON the boiler with a long pushing of the button P2.
Led status when the boiler is ON:
1.
The Ignition is signalled by the first blinking than
fix
led L1
2.
The Work state is signalled by the
fix led L4
3.
The Modulation state is signalled by the
blinking L4
If the ignition is not succeed during the predefined time (time out) the controller will turned OFF
and the error message “Err12” will be displayed.
WARNING
•
An odour of the paint can be felt while the boiler fired up for the first
time.
•
Do not open the combustion chamber door during operation.
•
Never fill the burner pot with pellets by hand. Excessive combustion
material in the burner pot means that the pellets will not be ignited
optimally.