Cortina S manuel Ver.01
17
7 OPERATION
Control Panel: Use and Functions
Led
P1
P2
P3
P4
START
STOP
SET
TA
OFF
ESC
D1
D2
D3
D4
L1
L3 L4
L5 L6 L7 L8
Led
Fix
Blinking
L1
Stabilization phase
Ignition Start phase
L3
Burner OFF
Extinguishing phase
L4
Work phase
Modulation/Standby phase
L5
Auger ON
-
L6
Igniter Resistance ON
-
L7
-
External Thermostat open
L8
Pump
-
Display
Display
Fix
Blinking
D1
Work Combustion Power
Set
D2
Boiler Thermostat Set
Combustion Power Change
D3
Boiler Temperature
Boiler Thermostat Change
D4
I
indicates the Pellet
recipe 1
II
indicates the Pellet
recipe 2
-
Buttons
Button
Click [P click]
Long Pressure [P long]
P1
Display other data / Esc
Pellet recipe selection
P2
Set in to the Menu function
Burner Start / Stop
P3
Thermostat Setting/ Increasing Value / Scroll
Menu
Pellet Loading Correction
P4
Combustion Power Setting/Decreasing
Value/Scroll Menu
Manual Pellet Loading
Alarms
Safety Thermostat (boiler) HV1: always signalled
Block
Safety Thermostat (pellet) HV2: always signalled
Block
Extinguishing for Lack of Flame
Block
Extinguishing for Water over Temperature
Block
Extinguishing for Exhaust gas over Temperature
Block
Encoder Error: No Encoder Signal
Block
Encoder Error: Combustion Fan regulation failed
Block
Failed Ignition
Block
Lack of fuel
Block
Anomaly in probe control during Check Up phase
The reset of the BLOCK Condition is done by the Long Pressure of the button P2