FIREpOwER Fp-95
INSTALLATION
Manual 0-5122
3-2
Installation
3.05 Requirements for Maximum Output
In order to obtain the maximum output capability of the
FirePower 95, a branch circuit capable of 20 amperes at
115 to 125 Volts 60 Hz is required. This generally applies
when welding steel that is equal to or greater than 12
gauge (0.105” 2.5mm) in thickness.
The rated output with this installation is 85 amperes, 18.25
Volt, 17% duty cycle (1 minute 40 seconds out of every
10 minutes used for welding).
3.06 Installing Wire Spool
As delivered from the factory, the unit is set with a 4”
(102mm) spool.
Installation of wire Spool
Assemble parts in sequence (shown in Figure 3-1 from
right to left).
1. Retaining Spring
2. "D" Washer
3. Spool
4. Locking knob (press the two tabs to remove it).
Spring
Hub
D-Ring
Wire Spool
Spool Locking
Knob
Art # A-09088
Figure 3-1: 4" Spool Installation