INTRODUCTION
Manual 0-5122
2-2
Introduction
2.05 Handle and Foot Assembly
1
2
3
4
Art # A-09101
2.06 Specifications
Description
Firepower FP-95
Package System Part Number
1444-0322
Power Source Weight
37.15 lb ( 16.8 kg)
Power Source Dimensions HxWxD
14"x7"x15"
(355.6 x 177.8 x 381mm)
Number of Phases
1 Ø
Frequency
60Hz
Flexible Supply Cable Size
7 ft (2.25 m) 14AWG
Supply Lead Plug Type
5-15P
Nominal Input Voltage
120V AC
Rated Input Current
15A
Rated kVA @ 100% Duty Cycle
1.2kVA
Rated Input Current
15A (60A@20%)
Maximum Input Current
28A (85A@17%)
Generator Requirements
98145.4519
98145.4519
# 3.4kVA
Open Circuit Voltage Range
15 – 27V
Output Current Range
23 – 90A
Duty Cycle Period
10 Minutes
Number of Output Voltage Values
2
Minimum Mains Circuit to suit factory fitted Plug &
Lead (Weld Current @ Duty Cycle)
(+) 15A (60A@20%)
Maximum Mains Circuit to suit factory fitted Plug &
Lead (Weld Current @ Duty Cycle)
(+) 28A (85A@17%)
Wire Size Range (Flux Core)
.023” - .030”
(0.6 - 0.8mm)
Table 2-1: System Specifications