Figure 4 – Gas Supply Location

Be sure the unit being installed is compatible with
the type of gas available. 
The range is shipped from the
factory for use with natural gas.  Conversion for use with
propane gas can be made by using a kit, NLPKIT 6 P/N 35-
00-688.  Only  a qualified technician or installer can convert
the range.  This kit includes instructions for adjusting valves
and pressure regulator and contains new burner jets. The
RDDS model is equipped with an intermittent/interrupted
ignition device (ExtraLow

®

).

CAUTION:  When connecting unit to propane gas,
make certain the propane gas tank is equipped with
its own high pressure regulator in addition to the
pressure regulator supplied with the appliance.  The
gas supply to the appliance regulator must be a
minimum of 11.0" water column. The maximum gas
pressure to the appliance regulator is not to exceed
14.0" water column from the propane gas tank.

6"

3" From Floor

1-3/4" From Wall

4-1/8" From
 Cabinet  Both
 Sides

ATTENTION:  En branchant l'appareil au gaz de
propane, soyez certain que le réservoir de gaz du
propane est équipé avec son régulateur de haute
pression en addition du régulateur de pression fourni
avec cet appareil.  La founriture de gaz au régulateur
de l'appareil doit être un minimum de 11.0" colonne
d'eau.  La pression de gaz maximale à cet appareil ne
doit pas excéder une colonne d'eau de 14.0 pounces
du régulateur du réservoir de gaz du propane.

WARNING:  Do not attempt any adjustment of the
pressure regulator except conversion to propane.

AVERTISSEMENT:   Ne pas entreprener aucun
ajustement du régulateur de la pression excepte la
conversion à propane.

GAS CONNECTION (MODEL RDDS30V)

GAS PRESSURE (INCH WATER COLUMN)

GAS

SUPPLY

MANIFOLD

Natural

 6 TO 14

 5

Propane

11 to 14

10

IMPORTANT NOTES

(a) The appliance and its individual shut-off valve must be
disconnected from the gas supply piping system during any
pressure testing of that system at test pressures in excess
of 1/2 psig (3.5kPa).

(b)  The appliance must be isolated from the gas supply
piping system by closing its individual manual shut-off valve
during any pressure testing of the gas supply piping system
at test pressures equal to or less than 1/2 psig (3.5 kPa).

Always use pipe dope or Telflon®  tape on the
pipe threads and be careful not to apply
excessive pressure when tightening the
fittings.

Turn on gas and check supply line connections
for leaks using a soap solution.  Do not use a
flame of any sort.

PROPANE GAS

NATURAL GAS
The cooktop is shipped from the factory for use with natural
gas only.  The gas supply to the appliance regulator must be
a minimum of 6.0" water column.  The maximum gas
pressure to the range regulator shall not exceed 14" W. C.

For Massachusetts Installations:

1. Shut-off valve must be a “T” handle gas cock.
2. Flexible gas connector must not be longer than

36 inches.

3. Not approved for installation in a bedroom or

a bathroom unless unit is direct vent.

Summary of Contents for RDDS30V

Page 1: ...GAZ Ne pas essayer d allumer aucun appareil Ne pas toucher aucun interrupteur lectrique ne pas utiliser aucun t l phone dans votre b timent Appeler imm diatement votre fournisseur de gaz du t l phone...

Page 2: ...tion appropri e des gaz par le conduit de fum e chemin e des appaeils combustible pour viter le refoulement Suivre la directive des fabricants du mat riel chauffant et les normes de s curit tel que ce...

Page 3: ...rface and the bottom of an unprotected wood or metal cabinet or 24 inches when bottom of wood or metal cabinet is protected by not less than 1 4 of flame retardant material covered with not less than...

Page 4: ...ve the existing back brace see Figure 27 Page 18 and use floor mounted anti tip bracket see Figure 30 Page 19 NOTE Follow all measurements precisely If working with nonstandard cabinets take care to a...

Page 5: ...au de 14 0 pounces du r gulateur du r servoir de gaz du propane WARNING Do not attempt any adjustment of the pressure regulator except conversion to propane AVERTISSEMENT Ne pas entreprener aucun ajus...

Page 6: ...If local code requires separate ground separate white wire and bare gound wire connect white to white and ground bare wire separately GAS CONNECTION MODEL RDDS30V GAS CONNECTION For gas units a 1 2 N...

Page 7: ...wer Cord Receptacle Integral Blower Front Rail 2 Units using Remote Blower a Wiring the Remote Blower Wire connections between the range and remote blower shall be made as follows 1 Remove plenum cove...

Page 8: ...ust to roof angle Tape all joints to prevent air leaks NOTE The unit must be sealed between the roof or wall and the underside of the flange with roofing mastic to prevent leaks For installation on a...

Page 9: ...ng See pages 10 to 12 for specific installation steps Threaded rods included in the blower kit will be secured to the mounting nuts A or B shown in Figure 15 Further installation instructions are spec...

Page 10: ...nsure gasket between blower and plenum is compressed 1 Determine blower direction and cutout in cabinet as shown in Figs 16 17 Remove the existing 1 4 20 screws from either positions A or B and discar...

Page 11: ...plenum outlet ring Figure 14 temporarily supporting blower with wood blocks 5 Place slot end of blower mounting bracket over rear mounting rod lower nut 6 Rotate blower mounting bracket under blower...

Page 12: ...rod has one preset nut which shall be tightened against plenum 4 Place blower inlet over plenum outlet ring Figure 14 temporarily supporting blower with wood blocks 5 Place slot end of blower mounting...

Page 13: ...to standard ducts See Figure 21 Exterior ducting may be routed right left rear up rear wall above and below floor line See Figure 22 VENTILATION Figure 21 Ducting Adapters Model RD7 Model RD310 REMOT...

Page 14: ...will need to transition from other duct sizes to achieve the 10 diameter Be sure to use proper transitions from one size duct to another NOTE You need to calculate the equivalent lengths of straight d...

Page 15: ...420 C F M BLOWER DUCT SIZING Based on the blower position determine the required straight duct length and size and the number and types of elbows or transitions Calculate the total equivalent length u...

Page 16: ...16 BLOWER DUCT SIZING...

Page 17: ...Cap Round to 3 1 4 x 10 Round to 3 1 4 x 10 90 Elbow 45 Elbow 3 1 4 x 10 to 10 Dia Model 310TR10 Equiv Length 1 Ft Fitting Straight Dia Length 6 5 Ft 7 4Ft 8 3 Ft Fitting Straight Dia Length 6 1 Ft 7...

Page 18: ...shall allow the range back brace to slide under the anti tip bracket See Figure 26 c If necessary add spacer between bracket and wall to insure anti tip bracket engagement d Slide range into position...

Page 19: ...LATION Figure 29 Placement of Anti tip Bracket to Floor TopView 12345678901 12345678901 12345678901 12345678901 12345678901 12345678901 12345678901 12345678901 12345678901 12345678901 12345678901 1234...

Page 20: ...dor reserves the right to change specifications or design without notice Some models are certified for use in Canada Thermador is not responsible for products which are transported from the United Sta...

Reviews: