Triangle Brush: 

The Triangle Brush may be used for diverse applications 
on many surfaces.  It can be used on almost any dry 
surface type including (but on limited to), Fabric, All 
Metals, Ceramic, Stone, Porcelain, Vinyl, Leather and 
Plastic. 

Generally, use of the triangle brush is dictated by the size of the object or surface being 
cleaned, rather than a specific surface type.  The Triangle Brush is used when the surface 
is too large to be cleaned with the Detail Tool or too small to be cleaned by the Wide 
Brush.  The Triangle Brush can also be used on large areas that are too dirty for the Wide 
Brush to work effectively. 
Use of a Cloth:  The Triangle Brush can be used with or without a cloth.  If a cloth is to be 

used, there are clips on the brush to attach the cloth.  When 
used without a cloth on a hard surface, the surface will need to 
be wiped with a clean, dry cloth immediately after passing over 
the surface with the Triangle Brush. 
Rough Textured surfaces:  It is more desirable to clean without a 
cloth or mitten over the brush. 

Fabrics:  A cloth is or is not necessary when cleaning fabrics.  Placing a cloth over the 
brush is not necessary when the desired goal is to sanitize the fabric more than to clean 
it.  To remove certain carpet stains, place a terry cloth or microfiber cloth on the stain 
and gently apply the brush to the stain.  The stain will incrementally be driven into the 
cloth.  Gradually move the cloth to absorb the stain into the clean areas of the cloth, 
until the stain is gone. 
Most of the time, better results will be achieved by placing a terry or microfiber cloth 
over the Triangle Brush.  This is done by placing the cloth on a smooth surface and neatly 
folding the cloth over the brush.  Push down on the clips (located on top of the brush) 
and tuck the cloth underneath.

 

  Release the clips and the cloth will be securely fastened 

to the brush.  When covered with an absorbent cloth, cleaning becomes a one-step 
process.  Simply wipe the surface slowly and all dirt and debris will be driven into the 
cloth, hard surfaces will usually dry in less than a minute. 

 
 
 
 
 
 

Summary of Contents for Therma-Steem XL1

Page 1: ...ry 14 2019 1 THERMA KLEEN Operators Manual Therma Steem Model XL1 Made in the USA THERMA KLEEN 2415 E Huron PO Box 805 Au Gres MI 48703 Ph 630 718 0212 Fax 989 876 6640 E mail sales therma kleen com W...

Page 2: ...RMATION 8 GROUNDING 8 OPERATING INSTRUCTIONS 10 SHUT DOWN 10 CONTROL PANEL 11 STEAM CONTROL VALVE 11 RESERVOIR TANK 11 LOW WATER ALARM 12 BOILER 12 DRAIN 12 HOSE MAINTENANCE 13 COOLING FAN 13 GUN TRIG...

Page 3: ...___________ City _________________________________ State __________ Zip Code __________ Telephone _________________________ E mail ______________________________ Serial ______________________ Date Shi...

Page 4: ...xpands forcing dirt and debris to the surface where the particulate is either suspended in a re condensed water molecule or driven into an absorbent cloth The dry vapor is super heated and is hot enou...

Page 5: ...IC PRECAUTIONS INCLUDING THE FOLLOWING 1 ALWAYS Check the machine power steam hose for damage prior to start up If damage is detected it must be repaired prior to use 2 CAUTION Before use check the el...

Page 6: ...ning ALWAYS keep your hands and body away from the nozzle tip during operation and wear appropriate protective clothing a DO NOT touch the steam nozzle while in use or until after it cools b DO NOT gr...

Page 7: ...rds gaskets and O rings 30 DO NOT try to repair your machine contact an Authorized Service Company or the factory Retain your box for shipping 31 DO NOT allow objects to get into the output nozzle Do...

Page 8: ...If the unit should malfunction or break down grounding provides a path of least resistance for the electrical current to pass reducing the risk of electrical shock All Therma Kleen units are equipped...

Page 9: ...nd ends and the blue light goes out indicating the pump has stopped it is now safe for you to activate the HEATER switch IMPORTANT NEVER turn ON the HEATER switch until the pump has stopped indicating...

Page 10: ...y location 8 NEVER store the unit in a freezing environment Frozen water will destroy the unit 9 NEVER ship or transport the unit unless it is completely empty of all water CONTROL PANEL A On Off swit...

Page 11: ...p stops pumping indicating that the boiler is full The blue light indicates that the boiler is calling for more water and water is pumping to the boiler The reservoir has a reservoir vent cap which co...

Page 12: ...ug is the other A flathead screwdriver may be used to remove plugs This will release the water Use caution since the water in the boiler may remain hot for a significant period of time Replace plugs c...

Page 13: ...trigger and release steam To lock simply swing the red lever down toward the handle Locked Unlocked MAINTENANCE BOILER Use distilled water to prevent accumulation of mineral deposits WARNING Exposing...

Page 14: ...water tank with this solution iv Turn on the unit allow it to heat up and steam out about of the mixture v Turn off the unit and let it rest for 30 minutes vi Repeat this process until the steam flow...

Page 15: ...ine into the correct voltage 220 480 575 3 phase 480 volt models This unit draws 23 amps Replace with 25 amp fast acting fuse See inside panel for style 575 volt models This unit draws 20 amps Replace...

Page 16: ...ature and pressure as it is being used STANDARD ACCESSORIES INCLUDED 1 25 ft Stainless Steel Hose with Trigger Gun 4031 1 Curved Nozzle Attachment 5013 1 Triangle Brush 5016 1 Blast Nozzle Attachment...

Page 17: ...he Triangle Brush Rough Textured surfaces It is more desirable to clean without a cloth or mitten over the brush Fabrics A cloth is or is not necessary when cleaning fabrics Placing a cloth over the b...

Page 18: ...ce When cleaning a rough textured surface it is more desirable to clean without a cloth over the brush Fabric surface same as Triangle Brush VAPOR VOLUME adjust the volume to about 3 8 Occasionally mo...

Page 19: ...ely removed Once clean wipe the surface with a dry absorbent cloth Clean hard to reach areas and corners first then proceed with the appropriate larger brush NYLON DETAIL BRUSH 1 Dia 2 1 2 Dia Use to...

Page 20: ...a surface and because they are fine they tend to penetrate deeper than other brush materials They are perfect for delicate jobs such as leather vinyl cloth porcelain scratch sensitive plastic Jewelry...

Page 21: ...art 5008 Fuse 208V 3 phase Part 5021 Curved Nozzle Attachment Part 5013 Fuse 220V 3 phase Part 5021 Zero Degree Blast Nozzle Part 5014 Fuse 480V 3 phase Part 5010 Triangle Brush Part 5016 Fuse 575V 3...

Page 22: ...Therma Steem Model XL1 January 14 2019 22 XL PUMP BREAKDOWN For your convenience we have included a breakdown of the XL pump This pump can be repaired with the parts listed on the previous page...

Page 23: ...HERMA KLEEN Inc 4 any consequential or incidental damages arising from the use of a THERMA KLEEN 5 damage due to misapplication or misuse Pump valves and bearings on the Ultra models are not warrantie...

Page 24: ...iability whatsoever in connection therewith No person including any dealer or representative of THERMA KLEEN Inc is authorized to make any representation or warranty concerning THERMA KLEEN Inc produc...

Reviews: