Therma-Steem® Model XL1
January 14, 2019
10
indicator light) can then be pushed, which will then re-activate the heater. An
empty boiler takes approx. 30 minutes to fill.
SHUT DOWN:
1.
Turn HEATER and MAIN power switches to
“OF
F
”
positions
2.
Unplug machine.
3.
Release steam from boiler by depressing trigger on gun.
4.
Close the steam control knob on the side of the machine.
5.
Unscrew the steam hose before storing on brackets.
6.
Drain any water which may be in the unit.
7.
Store in a warm dry location.
8.
NEVER
store the unit in a freezing environment. Frozen water will
destroy the unit.
9.
NEVER
ship or transport the unit unless it is completely empty of all
water.
CONTROL PANEL;
A
On/Off switch (left) for Main Power with GREEN indicator light (right).
B
On/Off switch (left) for heater with AMBER indicator light (right).
C
Add water WHITE indicator light.
D
BLUE indicator light comes on when the boiler is being filled.
E
Low water (RED blinking) indicator light.
F
Reset button for low water alarm.
G
Fuse holder with ABC 3 amp/ 110-volt fuse
H
Temperature Control-DIN.
I
Water Reservoir vent cap (on top of machine, not shown).
J