Position the inner rail on the side of the product with the safety catch toward the rear.
•
Align the rear hole of the rail with the rear hole on the chassis and attach using the M4 x 6mm screws
provided.
•
Align the other 4 holes with the counter sink in the rail with the corresponding holes in the chassis, insert
the M4 x 6mm screws, and tighten all the screws.
•
Repeat this to attach the second inner rail to the other side of the chassis.
d) Adjust rail length. (The rails support a range of rack mounting depths.)
•
Loosen the two rear retaining plate screws to enable the rear bracket to be extended.
e) Install outer rails into the rack.
•
Align the bracket marked “FRONT” with the holes in the front post.
•
Once aligned, push the bracket forward until the snap mechanism engages.
•
Slide the rear bracket towards the rear post of the rack.
•
Align the bracket with the holes in the rear post at the same vertical position used for the front and snap
it in.
•
Tighten the two rear retaining screws.
Attention:
Slide the bearing retainer all the way forward to avoid damaging the rail kit when the product is
installed.
f) Insert product into the outer rails.
•
With both the left and right bearing retainers moved the entire way forward, align the inner rails mounted
on the product with the outer rails mounted in the rack.
•
You may need to apply gentle pressure to the ends of the inner rails to align them with the outer rails.
•
Slide the product into the rack until the safety latches engage.
g) Push the safety catches in on both sides and slide the product fully into the rack. When sliding the unit into
the rack for the first time, the last few inches of travel may experience some resistance as the bearing
retainers meet their backstops. The resistance can be overcome by applying slightly more force to the front
of the unit to achieve full insertion into the rack.
10. Physically lock the unit into the rack.
•
Each key holder inserts their key into their respective lock and turns the lock to the locked position.
11. Connect your HSM to your Host using an Ethernet connection.
12. Connect the power cables.
13. Push the power switch (located on the back of the unit) to turn the unit on.