MANUAL P/N 900000165 REV H
51
SYNTAX INTEGER
{ sysOK (0),
sysFATAL (1),
sysWARN (2),
sysNET (3),
sysINF (4),
sysERR (5)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION "Event type"
::={syslogEntry 4}
module OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION "Originating module"
::={syslogEntry 5}
function OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION "function within module"
::={syslogEntry 6}
description OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION "Description of event"
::={syslogEntry 7}
linuxlogTable OBJECT-TYPE
SYNTAX SEQUENCE OF LinuxlogEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "System log table"
::= {systemstatus 4}
linuxlogEntry OBJECT-TYPE
SYNTAX LinuxlogEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "System log record"
INDEX {line}
::= {linuxlogTable 1}
LinuxlogEntry ::= SEQUENCE {
line INTEGER,
timestr OCTET STRING,
process OCTET STRING,
message OCTET STRING
}
line OBJECT-TYPE
SYNTAX INTEGER (1..2147483647)
ACCESS read-only
STATUS mandatory
DESCRIPTION "Event log index"
::={linuxlogEntry 1}
timestr OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION "Event type"
::={linuxlogEntry 2}
process OBJECT-TYPE
Summary of Contents for NTP80plus