Revolution Series PT-3500 / PT-7500 Puller Tensioner Page 74
Front Jack Lower Valve
Front jack valve in the retract
direction (CVA-7418 Section
3) is open or shorted. Fault
maintains when true; repower
control to clear.
Check harness connection at valve,
continuity or shorts between pins
and ground connection in harness.
Fault maintains when true; repower
control to clear.
Left Jack Lift Valve
Left jack valve in the extend
direction (CVA-7418 Section
5) is open or shorted. Fault
maintains when true; repower
control to clear.
Check harness connection at valve,
continuity or shorts between pins
and ground connection in harness.
Fault maintains when true; repower
control to clear.
Left Jack Lower Valve
Left jack valve in the retract
direction (CVA-7418 Section
5) is open or shorted. Fault
maintains when true; repower
control to clear.
Check harness connection at valve,
continuity or shorts between pins
and ground connection in harness.
Fault maintains when true; repower
control to clear.
Right Jack Lift Valve
Right jack valve in the extend
direction (CVA-7418 Section
4) is open or shorted. Fault
maintains when true; repower
control to clear.
Check harness connection at valve,
continuity or shorts between pins
and ground connection in harness.
Fault maintains when true; repower
control to clear.
Right Jack Lower Valve
Right jack valve in the retract
direction (CVA-7418 Section
4) is open or shorted. Fault
maintains when true; repower
control to clear.
Check harness connection at valve,
continuity or shorts between pins
and ground connection in harness.
Fault maintains when true; repower
control to clear.
Cold Start Bypass Valve
Cold start bypass valve (FV-
10705, Item 14) when in
operation is open or shorted.
Fault maintains when true;
repower control to clear.
Check harness connection at valve,
continuity or shorts between pins
and ground connection in harness.
Fault maintains when true; repower
control to clear.
Level Arm Lift Valve
Voltage output for PVG valve
(CVA-7418 Section 2) is open
or shorted. Fault maintains
when true; repower control to
clear.
Check harness connection at valve,
continuity or shorts between pins
and ground connection in harness.
Fault maintains when true; repower
control to clear.
Accessory Flow Valve
Spider accessory flow valve is
open or shorted. Fault
maintains when true; repower
control to clear.
Check harness connection at valve,
continuity or shorts between pins
and ground connection in harness.
Fault maintains when true; repower
control to clear.
Spider Level Wind Position
The actuator linear sensor for
spider level wind arm position
Check power and ground and sensor
input; Check Harness connection.
Summary of Contents for PT-3500
Page 1: ...PT 3500 PT 7500 Puller Tensioner Operators Manual...
Page 2: ......
Page 6: ......
Page 9: ......
Page 81: ......
Page 83: ...S R Revolution Series PT 3500 PT 7500 Puller Tensioner Page 79 Troubleshooting...
Page 84: ...S R Revolution Series PT 3500 PT 7500 Puller Tensioner Page 80 Fuse Relay Wiring Schematic...
Page 89: ......
Page 129: ...Revolution Series PT 3500 PT 7500 Puller Tensioner Page 121...
Page 131: ...Revolution Series PT 3500 PT 7500 Puller Tensioner Page 123...
Page 133: ...Revolution Series PT 3500 PT 7500 Puller Tensioner Page 125...
Page 134: ...Revolution Series PT 3500 PT 7500 Puller Tensioner Page 126 A...