Revolution Series PT-3500 / PT-7500 Puller Tensioner Page 107
Maintenance
Pre-Operation Inspection Checklist
(
Page 1)
1.
Check fuel level-
With key inserted in master power key switch, turn key to
the On position to activate the display. Once activated, the fuel level will
show on the color display.
2.
Ensure that the manual ignition switch is set to [REMOTE &
AUTO]
- located inside the engine compartment, accessible
through a round port cut in the engine cowling.
3.
Check for the
engine radiator
coolant level,
by viewing the
level on the coolant reservoir to
ensure that the fluid level is within
the
HI/LO
limits,
viewable
through a round port cut in the engine cowling.
4.
Check for proper engine oil level.
The dipstick
can be accessed through a round port cut in the
engine cowling. After checking oil level, wipe
dipstick clean of any debris prior to reinserting
into spout.
5.
Ensure proper hydraulic fluid level in reservoir
for
hydraulic system
, by viewing the sight gauge on the side
of the tank.
NOTE:
Pre-operation checklist
should
be conducted in accordance with OSHA requirements, to include OSHA
Standard- 29 CFR, Parts 1926.601, 1926.952, 1926.955, and 1926.150, as well as NFPA Standard No. 10-2013.
It is
recommended that pre-operation inspections be done before leaving the yard or garage.
NOTE:
It is necessary to remove the engine cover to access the main
ignition switch. Be sure the engine cover is replaced and latched in
position properly before transport or operating the machine.
NOTE:
It may be necessary to remove the engine cover to
check the oil level. Be sure it is replaced and secured in
position properly before transport or operating the
machine.
Oil Fill Port
Dipstick
Coolant
Summary of Contents for PT-3500
Page 1: ...PT 3500 PT 7500 Puller Tensioner Operators Manual...
Page 2: ......
Page 6: ......
Page 9: ......
Page 81: ......
Page 83: ...S R Revolution Series PT 3500 PT 7500 Puller Tensioner Page 79 Troubleshooting...
Page 84: ...S R Revolution Series PT 3500 PT 7500 Puller Tensioner Page 80 Fuse Relay Wiring Schematic...
Page 89: ......
Page 129: ...Revolution Series PT 3500 PT 7500 Puller Tensioner Page 121...
Page 131: ...Revolution Series PT 3500 PT 7500 Puller Tensioner Page 123...
Page 133: ...Revolution Series PT 3500 PT 7500 Puller Tensioner Page 125...
Page 134: ...Revolution Series PT 3500 PT 7500 Puller Tensioner Page 126 A...