Installation Guidelines
Installation
1. Install and wire meter per local applicable codes/reg-
ulations, the particular application, and good installation
practices.
2. Install meter in a location that does not exceed the
maximum operating temperature and that provides good
air circulation.
3. Separate input/output leads from power lines to
protect the meter from external noise. Input/output
leads should be routed as far away as possible from
contactors, control relays, transformers and other noisy
components. Shielding cables for input/output leads is
recommended with shield connection to earth ground
near the meter preferred.
4. A circuit breaker or disconnect switch is required
to disconnect power to the meter. The breaker/switch
should be in close proximity to the meter and marked as
the disconnecting device for the meter or meter circuit.
The circuit breaker or wall switch must be rated for the
applied voltage (e.g., 120VAC or 240VAC) and current
appropriate for the electrical application (e.g., 15A or
20A).
5. See
Case Dimensions section
for panel cutout infor-
mation.
6. See
Connector Pinouts section
for wiring.
7. Use 28-12 AWG wiring, minimum 90˚C (HH) tempera-
ture rating. Strip wire approximately 0.3 in. (7-8 mm).
8. Recommended torque on all terminal plug screws is
4.5 lb-in (0.51 N-m).
!