Exit Code 7.
Return to
Operational Display
CONFIGURING CH4 FUNCTIONS PROCEDURE
Pass Brightness Mode,
Calibration Mode, and
Codes 1 to 5 and enter
Code 6
Set Code 6 to [01X]:
1st Digit = 0 Selects direct display of
CH4 processed signal
2nd Digit = 1 Selects voltage, current
3rd Digit = X Not relevant
Save CH4 setting
From Step 4
Step 4
To
Step
5
Step 3
Step 1
Step 2
Operational Display
Enter Brightness Mode
SP1 SP2 SP3 SP4 SP5 SP6
Prog.
SP1 SP2 SP3 SP4 SP5 SP6
Prog.
Press
7
SP1 SP2 SP3 SP4 SP5 SP6
Prog.
Press
at same
time
Press
at same
time
SP1 SP2 SP3 SP4 SP5 SP6
Prog.
Step 5
Operational Display
SP1 SP2 SP3 SP4 SP5 SP6
Prog.
SP1 SP2 SP3 SP4 SP5 SP6
Prog.
SP1 SP2 SP3 SP4 SP5 SP6
Prog.
SP1 SP2 SP3 SP4 SP5 SP6
Prog.
OR
Press
at same
time
Press
at same
time
CONFIGURE CH4
FUNCTIONS
SP1 SP2 SP3 SP4 SP5 SP6
Prog.
Press
1
Initial Setup Procedures
[CodE_6] - Channel 4 Functions
CH4 POST PROCESSING
0 Direct Display of Input (no pro-
cessing)
1 Square Root of Channel 4
2 Inverse of Channel 4
3
4 kB Meters
32-point Linearization of CH4 using
Table 1
32 kB Meters
32-point Linearization of CH4 using
Table 4
Note:
All linearization tables are set up
in the Calibration Mode [24X].
CODE 6 – CHANNEL 4 FUNCTIONS
FIRST DIGIT
SECOND DIGIT
THIRD DIGIT
FOR THERMOCOUPLE
0 Type J
1 Type K
2 Type R
3 Type S
4 Type T
5 Type B
6 Type N
7 Select user defined lineariza-
tion table (Table 1) set up in CAL
[24X]
FOR RTD TYPE (2-, 3-, 4- WIRE)
0 Resistance
1 RTD 385
2 RTD 392
3 RTD 120
4 Cn 10
MEASUREMENT TASK
0 No Function
1 Voltage / Current
2 TC (3rd digit selects type of
TC).
See Note 7
3 RTD (3rd digit selects type of
RTD).
See Note
7
4 Real Time Clock and Timer (3rd
digit selects type)
5 -
6 -
7 Smart Input Module (3rd digit
selects register)
FOR SMART INPUT MODULE
0 Output Register 1
1 Output Register 2
2 Output Register 3
3 Output Register 4
4 Output Register 5
5 Output Register 6
6 Output Register 7
7 Smart Input Module Register 3
Code Setup
Note 7:
For future development.
FOR REAL-TIME CLOCK & TIMER
0 HRS:MIN:SEC
1 HRS:MIN
2 -
3 -
4 1 Second Count UP Timer
5 1 Second Count DOWN Timer
6 -
7 -
P
Press
Use the
buttons to set the
required smart input module code
(0 to 377). See
I-Series Input
Module Guide (Z87)
for code
details.
Code 6 is a single code that
combines all the configuration
and post processing functions
available for Channel 4.
When a
quad input
signal con-
ditioner is installed, the fourth
input signal is processed and
displayed on CH4.
Post processing and measure-
ment task functions for CH4
are configured in the 1st, 2nd,
and 3rd digits of Code 6. The
diagram opposite lists the avail-
able configuration selections in
Code 6.
Example Procedure:
Configure CH4 for a
direct display of voltage input
by
setting Code 6 to [
01X
].
See
I-Series Input Modules Guide (Z87)
for pro-
cedures to set up a quad input module.