Software Logic Tree
The
CL-B101D40HZ
is an intelligent bargraph meter with a hier-
archical software structure designed for easy programming and
operation, as shown below in the software logic tree.
v
When power is applied, all segments of the bargraph and
digital display light up for 3 seconds. The version number of
the installed software is then displayed for 2 seconds, after
which, the operational display indicates the input signal.
15 Second Program Timeout
Except for ZERO and SPAN settings in the Two
Point Digital Calibration Mode and the Analog
Output Range Setting and Calibration Mode
(cLo and chi), the meter has a 15 second
program timeout. If no buttons are pressed for
15 seconds in any of the other programming
sequences, the meter will exit the program-
ming mode and return to the operational
display. Any program changes that were made
prior to pressing the
P
button in the preced-
ing step will not be saved.
Peak
Reset
PEAK
Reset
VALY
Valley
PEAK & VALLEY
VIEW & RESET
Operational Display
MAIN MENU
Bargraph Center Point
Display Selection (cto)
This branch will
only appear if
the analog
output option
is installed
Back to
Operational
Display
Digital Display ON/OFF
Selection (diSP)
Sub-menu MODE
Calibration Mode
Calibration
Input
Calibration
Output
offset
(ZEro)
Scale
Factor
(SPAn)
Calibrate Analog
Output Lo
Calibrate Analog
Output Hi
Select the Digital
Reading at which
the Analog Output
Hi (chi) will occur
Select the Digital
Reading at which
the Analog Output
Lo (cLo) will occur
This branch will only
appear, if the analog
output option
is installed
DIGITAL SPAN SELECTION
FOR ANALOG RANGE OUTPUT
See Page 6
DIGITAL DISPLAY ON/OFF
See Page 6
RANGE SELECTION
See Page 7
BARGRAPH CENTER POINT
DISPLAY MODE SELECTION
See Page 6
TWO POINT ANALOG OUTPUT
RANGE SETTING AND CALIBRATION
See Page 7
Set the Decimal
Point (dp)
Bargraph Display
Scale Lo Range
Setting (bLo)
Bargraph Display
Scale hi Range
Setting (bhi)
Display
Brightness (br)
1 Dimmest
2 Dim
3 Bright
4 Brightest
[X•XXX]
[XX•XX]
[XXX•X]
[XXXX•]
[XXXX]
DECIMAL POINT AND
BRIGHTNESS SELECTION
See Page 5
DIGITAL SPAN SELECTION
FOR BARGRAPH DISPLAY
See Page 5
Goes directly
to Zero setting
if Analog Output
is not installed
+
–
4.00
+
–
20.00
Range
[99•99]
[9999]
[999•9]
Select one of three
Ranges: 99.99Hz,
999.9Hz or 9999Hz
PROGRAMMABLE
OFFSET AND
SCALE FACTOR
See Page 4
[orAn]
[rEd]
NOTE: Will only
appear if a tricolor
display is installed
[orAn]
[rEd]
[orAn]
[rEd]
[orAn]
[rEd]
[orAn]
[rEd]
BARGRAPH COLOR
PROGRAMMING MODE
See Page 10
Tricolor Bargraph
The tri-color bargraph is designed
like a traffic light, to display either
red, orange or green, but only one
color at a time. The color to be
displayed is selected in two ways.
The first step is to select the color
to be displayed when the bar is
“below” whichever set point is set
to the lowest position.
The second step is to select the
color to be displayed when the bar
is above each specific setpoint,
regardless of the order or position
to which the set points are set.
However, if two or more setpoints
with differently specified colors are
positioned at the same set point
value, the color specified for the set
point with the highest identifying
number will be displayed. When
setpoints are set to the same value,
the SP4 color overrides the SP3
color, the SP3 color overrides the
SP2 color, and the SP2 color
overrides the SP1 color.
SETPOINT SETTING AND
RELAY CONFIGURATION MODE
See Page 9
L or h
L or h
L or h
L or h
Relays
Activation [rLYS]
(h) High
the relay
energizes
when the setpoint
is exceeded
(L) Low
the relay
energizes below
the setpoint.
Pump On Pump Off [PUM]
When PUM is selected on,
and SP2 is set at a value
higher than SP1, the SP1
relay will operate in a special
"pump on pump off"
Hysteresis mode. SP2 acts
as the upper limit and SP1
acts as the lower limit of the
Hysteresis Band.
For filling applications, rLYS
should be set to LhLh. SP1 will
then activate for inputs less than
the SP1 setpoint, and remain
ON until the SP2 setpoint is
reached.
For emptying applications,
rLYS should be set to hhhh.
SP1 will then activate for inputs
greater than the SP2 setpoint,
and remain ON until the SP1
setpoint is reached.
Set Setpoint 1
[SP1]
Delay-on-Make
[doM]
Delay-on-Break
[dob]
Setpoint 2
[SP2]
NOTE: [dom] [dob]
Functions are only
available for SP1
0 to 9999
seconds
0 to 9999
seconds
Pump
[PUM]
Hysteresis
[hYSt]
Hysteresis
[hYSt]
Hysteresis
[hYSt]
Hysteresis
[hYSt]
Setpoint 3
[SP3]
Setpoint 4
[SP4]
BRIGHTNESS AND
SETPOINT VIEW MODE
1 Dimmest
2 Dim
3 Bright
4 Brightest