background image

BASIC MODEL #

DISPLAY

POWER SUPPLY

INPUT MODULES

ANALOG OUTPUT

RELAY OUTPUT

OPTIONS / ACCESSORIES

OA____

Page 14

CL-B101D40HZ Manual (d0098)

CL-B101D40HZ

Add to the basic model number the order code suffix for each standard option required. The last suffix is to 

indicate how many different special options and or accessories that you may require to be included with this product. 

Ordering Example: CL-B101D40HZ-VRR-PS1-IF08-OIC-R11-OA1 (Range Change) 

Ordering Information

WARRANTY

Texmate warrants that its products are free from defects in material and workmanship under 

normal use and service for a period of one year from date of shipment. Texmate’s obligations 

under this warranty are limited to replacement or repair, at its option, at its factory, of any of 

the products which shall, within the applicable period after shipment, be returned to Texmate’s 

facility, transportation charges pre-paid, and which are, after examination, disclosed to the 

satisfaction of Texmate to be thus defective. The warranty shall not apply to any equipment 

which  shall  have  been  repaired  or  altered,  except  by  Texmate,  or  which  shall  have  been 

subjected to misuse, negligence, or accident. In no case shall Texmate’s liability exceed the 

original purchase price. The aforementioned provisions do not extend the original warranty 

period of any product which has been either repaired or replaced by Texmate.

USER’S RESPONSIBILITY

We  are  pleased  to  offer  suggestions  on  the  use  of  our  various  products  either  by  way  of 

printed matter or through direct contact with our sales/application engineering staff. However, 

since we have no control over the use of our products once they are shipped, NO WARRANTY 

WHETHER  OF  MERCHANTABILITY,  FITNESS  FOR  PURPOSE,  OR  OTHERWISE  is  made 

beyond the repair, replacement, or refund of purchase price at the sole discretion of Texmate. 

Users shall determine the suitability of the product for the intended application before using, 

and  the  users  assume  all  risk  and  liability  whatsoever  in  connection  therewith,  regardless 

of any of our suggestions or statements as to application or construction. In no event shall 

Texmate’s liability, in law or otherwise, be in excess of the purchase price of the product.
Texmate cannot assume responsibility for any circuitry described. No circuit patent or soft

-

ware licenses are implied. Texmate reserves the right to change circuitry, operating software, 

specifications, and prices without notice at any time.

1934 Kellogg Ave., Carlsbad, CA 92008

Tel: 1-760-598-9899 • 1-800-TEXMATE

Fax: 1-760-598-9828 • Email: [email protected] 

 

BASIC MODEL NUMBER

CL-B101D40HZ   114x114mm, 101 Segment Circular Bargraph with 4 Digit  

 

                      Display  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . $595

Standard Options for this Model Number

 

Order Code Suffix 

Description 

List

DISPLAY

RR .  .  .  .  .  .Red Circular 101 Segment LED Bar with 4 Digit Red LED Display  .  .  .  .  .  .  .  . N/C

GR  . . . Green Circular 101 Segment LED Bar with 4 Digit Red LED Display . . . . . $15

TR . . . . . .Tri-Color Circular 101 Segment LED Bar with 4 Digit Red LED Display . . . . $50

POWER SUPPLY

PS1  .  .  .  .  .85-265VAC/95-300VDC   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . N/C

 

PS2. . . . .18-48VAC/10-72VDC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . $40

INPUT MODULES (Partial List. See www.texmate.com)

Unless otherwise specified Texmate will ship all modules precalibrated with  

factory preselected ranges and/or scalings as shown in 

BOLD

 type.

 

IF05. . . . Universal Frequency / RPM 

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

IF08. . . . .Line Frequency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . $167

ANALOG OUTPUT

Note: If a meter is ordered with a Analog Output and/or Relay Output 

Module, an Output Module Carrier Board will be automatically added  

to the order.

OIC  . . . . .Isolated 16 Bit Current Output, 4-20mA  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . $46

OIV  . . . . .Isolated 16 Bit Voltage Output, 0-10VDC  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . $46

SA-CLCB Output Module Carrier Board  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . $30

RELAY OUTPUT MODULES  

Note: If a meter is ordered with a Analog Output and/or Relay Output 

Module, an Output Module Carrier Board will be automatically added  

to the order.

SA-CLCB  � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � �

Output Module Carrier Board� � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � $30

 

OR11 � One 10 Amp Form C Relay, Isolated  � � � � � � � � � � � � � � � � � � � � � $41 

OR15 � One 10 Amp Form C and Two 5 Amps Form A Relays  � � � � � � � $99 

OR16 � One 10 Amp Form C and One 5 Amp Form A Relays � � � � � � � � $76

OR12 � Two 10 Amp Form C Relays, Isolated  � � � � � � � � � � � � � � � � � � � � $81 

OR14 � Two 10 Amp Form C and Two 5 Amps Form A Relays  � � � � � � � $139

OR23 � Two 10 Amp Form C and One 5 Amp Form A Relay, Isolated� � $116

OR25  � One 9A Form C & two 4A Form A relays� Isolated�  � � � � � � � � � � $99 

OR31 � One 5 Amp Form A Relay, Isolated  � � � � � � � � � � � � � � � � � � � � � � $35

OR32 � Two 5 Amp Form A Relays, Isolated  � � � � � � � � � � � � � � � � � � � � � $70 

OR33 � Three 5 Amp Form A Relays, Isolated  � � � � � � � � � � � � � � � � � � � � $94 

OR34 � Four 5 Amp Form A Relays, Isolated  � � � � � � � � � � � � � � � � � � � � � $123 

CL-B101D40HZ Technical Manual Copyright © 2020 Texmate Inc. All rights 

reserved. Published by: Texmate Inc. USA. Information in this Technical Manual 

is subject to change without notice due to correction or enhancement. The 

information described in this manual is proprietary to Texmate, Inc. and may 

not be copied, reproduced or transmitted, in whole or in part, in connection with 

the design, manufacture, or sale of apparatus, device or private label product 

without the express written consent of Texmate, Inc.

Solid State Relay (SSR) Output Modules DC Only  

OR51 � One 400V DC Solid State Relay (SSR) 210mA� � � � � � � � � � � � � $35

OR52 � Two 400V DC Solid State Relays (SSR) 210mA  � � � � � � � � � � � � $70

OR53 � Three 400V DC Solid State Relays (SSR) 210mA� � � � � � � � � � � $94

OR54 � Four 400V DC Solid State Relays (SSR) 210mA� � � � � � � � � � � � $

123

Special Options and Accessories 

 

Part Number 

Description 

List

SPECIAL OPTIONS (Specify Inputs or Outputs & Req. Reading)

ZR. . . . . . . . . . . . . . . Range change from Standard Range shown in 

BOLD

 Type  . . . . . . . $20

ZS . . . . . . . . . . . . . . . Custom Digital Display Scaling within Stadard Ranges  . . . . . . . . . . . $24

CS-BAR  . . . . . . . . . . Custom Bargraph Display Scaling within Standard Range. . . . . . . . . $17

ZS-AO. . . . . . . . . . . . Custom Scaling of Analog Output  . . . . . . . . . . . . . . . . . . . . . . . . . . . $35

ART-FS1 . . . . . . . . . . Produce and install custom faceplate per meter - 1 color  . . . . . . . . . $55  

ART-FS2 . . . . . . . . . . Produce and install custom faceplate per meter - 2 color . . . . . . . . . $60 

ART-FS3 . . . . . . . . . . Produce and install custom faceplate per meter - 3 color . . . . . . . . . $65 

ART-FS4 . . . . . . . . . . Produce and install custom faceplate per meter - 4 color    . . . . . . . . $69

ART-NRC-DEC . . . . . NRC for Artwork & set-up Custom Faceplate and/or Descriptor  . . . . $100

ACCESSORIES (Specify Serial # for Custom Artwork Installation)

93-PLUG2P-DP. . . . . . Extra Screw Terminal Conn., 2 Pin Power Plug  . . . . . . . . . . . . . . . $3

93-PLUG2P-DR  . . . . . Extra Screw Terminal Conn., 2 Pin Plug. . . . . . . . . . . . . . . . . . . . . $3

93-PLUG3P-DR  . . . . . Extra Screw Terminal Conn., 3 Pin Plug. . . . . . . . . . . . . . . . . . . . . $5

93-PLUG4P-DR  . . . . . Extra Screw Terminal Conn., 4 Pin Plug. . . . . . . . . . . . . . . . . . . . . $6

93-PLUG5P-DR  . . . . . Extra Screw Terminal Conn., 5 Pin Plug. . . . . . . . . . . . . . . . . . . . . $7

Prices subject to change without notice

Summary of Contents for CL-B101D40HZ

Page 1: ...Mode Selection 6 Bargraph Color Programming Mode 9 Case Dimensions 13 Component Layout 11 Connector Pinouts and Pin Descriptions 10 11 Controls and Indicators 2 Decimal Point and Brightness Selection...

Page 2: ...irection indicated by the arrow When an alternative dotted line is shown this indicates that an alternative logic branch will be followed when a particular option is present When two buttons are shown...

Page 3: ...See Page 5 Goes directly to Zero setting if Analog Output is not installed 4 00 20 00 Range 99 99 9999 999 9 Select one of three Ranges 99 99Hz 999 9Hz or 9999Hz PROGRAMMABLE OFFSET AND SCALE FACTOR...

Page 4: ...6 meter may be rescaled without applying an external signal by changing the Offset and Scale factor Offset is the reading that the meter will display for a zero input The Offset may be set to any valu...

Page 5: ...this point the display skips directly to STEP G and toggles between Cto and oFF the software is detecting that the optional analog output hardware is NOT installed Digital Span Selection For Bargraph...

Page 6: ...h and AnLo analog low can be reversed to provide a 20 to 4mA output The digital span selected can be as small as two counts when using the analog output to function as a Control or Alarm Driver Small...

Page 7: ...volt output selected However the output of cLo must always be less than the value selected for chi If a reversed analog output is desired the values selected to establish the Digital Span can be reve...

Page 8: ...ress the P button Display toggles between PUM and on or oFF STEP F Select Pump PUM on or oFF 1 Using the and buttons select the Pump to be ON or OFF When PUM is selected ON and SP2 is set at a value h...

Page 9: ...argraph Color when the bar is ABOVE SP2 Setpoint 1 Using the and buttons select the desired bargraph color grn oran or red 2 Press the P button Display toggles between CSP3 and the previous color sett...

Page 10: ...mp Form A relays An analog output module is also shown as installed The CL B101D40HZ uses plug in type screw terminal connectors for all input and output connections The power supply connec tions pins...

Page 11: ...A SP4 SP3 SP2 SP1 SP1 SP2 SP3 SP4 Relay Modules with 4 Isolated 5A Form A Relays Output Carrier Board Output Carrier Board Relay Module Relay Module Input Signal Conditioner Analog Output Module Main...

Page 12: ...ditioning Modules COUPLING INPUT SIGNAL FILTER MAG NAMUR SOURCE SINK LOAD AC 20KHz 2KHz 200Hz OFF DC MAG AC LOGIC GND 24V INPUT High Accuracy Digital Measurement NPN Open Collector Proximity Switch No...

Page 13: ...t the meter from external noise Input output leads should be routed as far away as possible from contactors control relays transformers and other noisy components Shielding cables for input output lea...

Page 14: ...y 50 POWER SUPPLY PS1 85 265VAC 95 300VDC N C PS2 18 48VAC 10 72VDC 40 INPUT MODULES Partial List See www texmate com Unless otherwise specified Texmate will ship all modules precalibrated with factor...

Reviews: