CL-B101D40HZ Manual (d0098)

Page 11

29

28 27

25

26

24 23 22

DL Series

Options

4A

4A

Order Code

OR11

OR12

OR23

OR14

-

-

-

-

-

-

-

4A

4A

4A

4A

10A

-

-

OR15

OR16

SP2

SP4

SP1

SP3

9A

9A

9A

9A

9A

9A

9A

9A

SP3

SP1

SP4

SP2

Relay Modules with 2 Non-Isolated 4A Form A Relays,

and 2 Non-Isolated 9A Form C Relays

29

28 27

25

26

24 23 22

DL Series

Options

Order Code

OR51
OR52

OR53

OR54

-
-
-

-

-

-

210mA
210mA

210mA

210mA

210mA

210mA

210mA

210mA

210mA

210mA

SP4

SP3

SP2

SP1

SP4

SP3

SP2

SP1

Relay Modules with 4 Independent 300V

(210mA DC only)

29

28

27

25

26

24

23

22

DL Series

Options

Order Code

OR31

OR32

OR33

OR34

-

-

-

-

-

-

5A

5A

5A

5A

5A

5A

5A

5A

5A

5A

SP4

SP3

SP2

SP1

SP1

SP2

SP3

SP4

Relay Modules with 4 Isolated 5A Form A Relays

Output

Carrier

Board

Output

Carrier

Board

Relay 

Module

Relay 

Module

Input Signal 

Conditioner

Analog Output 

Module

Main 

Board

Display 

Board

Component Layout

Component Layout

Connector Pinouts continued

AC/DC Power Input- Pins 14 and 15 

Auto-sensing AC/DC power supply� For voltages between 

85-265 V AC/95-300 V DC (PS1) or 18-48 V AC/10-72 V DC (PS2). 

Pin 14  AC/DC Neutral. Neutral power supply line� 

Pin 15  AC/DC line. Live power supply line�

Optional Carrier Board Output Pins

Analog Output- Pins 16 and 17  

Pins 16 and 17 are the analog output pins on the optional 

output module� Their pin definitions are: 

Pin 16    Positive (+) analog output� 

Pin 17    Negative (–) analog output�

RS-485 Output- Pins 19, 21 and 21

Pins 22 to 29 – Output Module Pins

Summary of Contents for CL-B101D40HZ

Page 1: ...Mode Selection 6 Bargraph Color Programming Mode 9 Case Dimensions 13 Component Layout 11 Connector Pinouts and Pin Descriptions 10 11 Controls and Indicators 2 Decimal Point and Brightness Selection...

Page 2: ...irection indicated by the arrow When an alternative dotted line is shown this indicates that an alternative logic branch will be followed when a particular option is present When two buttons are shown...

Page 3: ...See Page 5 Goes directly to Zero setting if Analog Output is not installed 4 00 20 00 Range 99 99 9999 999 9 Select one of three Ranges 99 99Hz 999 9Hz or 9999Hz PROGRAMMABLE OFFSET AND SCALE FACTOR...

Page 4: ...6 meter may be rescaled without applying an external signal by changing the Offset and Scale factor Offset is the reading that the meter will display for a zero input The Offset may be set to any valu...

Page 5: ...this point the display skips directly to STEP G and toggles between Cto and oFF the software is detecting that the optional analog output hardware is NOT installed Digital Span Selection For Bargraph...

Page 6: ...h and AnLo analog low can be reversed to provide a 20 to 4mA output The digital span selected can be as small as two counts when using the analog output to function as a Control or Alarm Driver Small...

Page 7: ...volt output selected However the output of cLo must always be less than the value selected for chi If a reversed analog output is desired the values selected to establish the Digital Span can be reve...

Page 8: ...ress the P button Display toggles between PUM and on or oFF STEP F Select Pump PUM on or oFF 1 Using the and buttons select the Pump to be ON or OFF When PUM is selected ON and SP2 is set at a value h...

Page 9: ...argraph Color when the bar is ABOVE SP2 Setpoint 1 Using the and buttons select the desired bargraph color grn oran or red 2 Press the P button Display toggles between CSP3 and the previous color sett...

Page 10: ...mp Form A relays An analog output module is also shown as installed The CL B101D40HZ uses plug in type screw terminal connectors for all input and output connections The power supply connec tions pins...

Page 11: ...A SP4 SP3 SP2 SP1 SP1 SP2 SP3 SP4 Relay Modules with 4 Isolated 5A Form A Relays Output Carrier Board Output Carrier Board Relay Module Relay Module Input Signal Conditioner Analog Output Module Main...

Page 12: ...ditioning Modules COUPLING INPUT SIGNAL FILTER MAG NAMUR SOURCE SINK LOAD AC 20KHz 2KHz 200Hz OFF DC MAG AC LOGIC GND 24V INPUT High Accuracy Digital Measurement NPN Open Collector Proximity Switch No...

Page 13: ...t the meter from external noise Input output leads should be routed as far away as possible from contactors control relays transformers and other noisy components Shielding cables for input output lea...

Page 14: ...y 50 POWER SUPPLY PS1 85 265VAC 95 300VDC N C PS2 18 48VAC 10 72VDC 40 INPUT MODULES Partial List See www texmate com Unless otherwise specified Texmate will ship all modules precalibrated with factor...

Reviews: