Page 1: ...IMPORTANT Read before Using RECHARGEABLE LASER DISTANCE MEASURE www prexiso eu com 2 WARRANTY LIMITED YEARS P15M 3LI P15M 3LI ...

Page 2: ...modified Carry out periodic test measure ments Particularly before during and after important measure ments The product and batteries must not be disposed of with household waste It is a Class 2 laser product in accordance with IEC 60825 1 2014 WARNING Table of Contents Safety Instructions Symbols used Permitted use Prohibited use Hazards in use Limits of use Areas of responsibility Electromagneti...

Page 3: ...t must ensure that all users understand these directions and adhere to them Display On Measure Continuous Measuring Charge the device Open the cap and insert the USB recharging cable with Mirco USB Port Recharge the device when battery symbol shows empty Battery Units Main line Measuring Reference Area Volume Pythagoras 2 Point 3 Point P15M 3LI P15M 3LI Micro USB Units Measuring Reference Area Vol...

Page 4: ...NITS Device is turned OFF Switch between the following units Operations Switching ON OFF Unit setting If no key is pressed for 120 sec the device switches off automatically 1 2 The system default measurements start at the bottom as a reference point Press button to change the reference to top for measurement UNITS ...

Page 5: ...uring to colourless liquids glass styrofoam or semi permeable surfaces or when aiming at hight gloss surfaces Against dark surfaces the measuring time increases Continuous measuring Area The result is shown in the main line and the measured distance above The last value measured is displayed Aim laser at first target point Aim laser at second target point Aim active laser at target 19 99 7 16 19 9...

Page 6: ...point 4 The result is shown in the main line and the measured distance above 3x Measuring Functions Volume The result is shown in the main line and the measured distance above Pythagoras 2 point Aim laser at first target point Aim laser at second target point Aim laser at third target point 19 99 7 16 29 99 3 ft ...

Page 7: ...3 point 1 2 Aim laser at first target point 3 Aim laser at second target point Perpen dicular to the measuring surface 4x 90 4 Aim laser at third target point 5 The result is shown in the main line and the measured distance above 19 99 7 16 ...

Page 8: ...g Shadow target area e g white paper The object is out of rated range Measure within rated range Beam is moved too fast Move the measuring tool slowly Range with favourable conditions Accuracy with favourable conditions Care Smallest unit displayed Laser class Laser type Weight Temperature range Storage Operation Technical Data The battery must not be disposed of with household waste Care for the ...

Page 9: ...s and adhere to them Watch out for erroneous measurements if the instrument is defective or if it has been dropped or has been misused or modified Carry out periodic test measurements Particularly after the instrument has been subject to abnormal use and before during and after important measurements Never attempt to repair the product yourself In case of damage contact a local dealer Changes or m...

Page 10: ...ents of the relevant standards and regulations However the possibility of causing interference in other devices cannot be totally excluded This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equip...