59
Mechanical
1. Cooling
--
Forced air cooling by internal fans.
2. Weight
Kg
Less than 8.5kg
3. Dimensions(W×H×D)
mm
W:422.8
、
H:43.6
、
D:432.8 ( Refer to Outline drawing )
Safety/EMC
1.Applicable standards:
Safety
EMC
--
UL60950-1.
Vout=60V: Output is SELV, GP-IB/Isolated analog are SELV.
60<Vout=400V: Output is hazardous, GP-IB/Isolated analog are SELV.
400<Vout=600V: Output is hazardous, GP-IB/Isolated analog are not SELV.
EN55024
2.Withstand voltage
--
Vout=60V models: Input-Outputs (SELV): 3.0KVrms 1min, Input-Ground: 2.0KVrms 1min,
60<Vout=600V models: Input-Haz. Output: 2.5KVrms 1min, Input-SELV: 3KVrms 1min,
Hazardous Output-SELV: 1.9KVrms 1min, Hazardous Output-Ground: 1.9KVrms 1min,
Input-Ground: 2.0KVrms 1min.
3.Insulation resistance
--
More than 100Mohm at 25°C
、
70%RH
4.Conducted emission
--
Conforms to EN55022B, FCC part 15-B, VCCI-B
5.Radiated emission
--
Conforms to EN55022B, FCC part 15-A, VCCI-A
Notes
:
*1: Minimum voltage is guaranteed to maximum 0.2% of the rated output voltage.
*2: Minimum current is guaranteed to maximum 0.4% of the rated output current.
*3: For cases where conformance to various safety standards (UL, IEC etc.) is required, to be described as 100Vac to 240Vac (50Hz/60Hz).
*4: At 100V/200V input voltage and maximum output power.
*5: From 85Vac to 132Vac or 170Vac to 265VAC, constant load.
*6: From No-load to Full-load, constant input voltage. Measured at the sensing point in Remote Sense.
*7: For load voltage change, equal to the unit voltage rating, constant input voltage.
*8: For 6V models the ripple is measured at 2V to 6V output voltage and full output current. For other models, the ripple is measured at 10% to 100% output voltage and full output current.
*9: With rated, resistive load.
*10: When parallel operation exceeding four sets is required, please contact to our company.
Supplemental characteristics
The supplemental characteristics data is held in each our sales and service facility. For further details please contact the our office nearest you.