56
APPENDIX C SPECIFICATIONS
Output rating
MODEL
6-200
8-180
12.5-120
20-76
30-50
40-38
60-25
80-19
100-15
150-10
300-5
600-2.6
1.Rated output voltage(*1)
V
6
8
12.5
20
30
40
60
80
100
150
300
600
2.Rated output current 1500w(*2)
A
200
180
120
76
50
38
25
19
15
10
5
2.6
3.Rated output power 1500w
W
1200
1440
1500
1520
1500
1520
1500
1520
1500
1500
1500
1560
Input characteristics
V
6
8
12.5
20
30
40
60
80
100
150
300
600
1.Input voltage/freq.(*3)
-
85VAC to 265VAC continuous,47Hz to 63Hz,single phase.
2.Input current(at 100VAC/200VAC)
A
21/11 for 1500W models.
3.Power Factor
-
0.99 @100VAC/200VAC, rated output power.
4.1500W models Efficiency (*4)
%
77/79
78/81
82/85
83/86
83/86
84/88
84/88
84/88
84/88
84/88
84/88
84/88
5.Inrysh current at 100V/200V
A
Less than 50A for 1500W models.
Constant voltage mode
V
6
8
12.5
20
30
40
60
80
100
150
300
600
1. Max. Line regulation (*5)
-
0.01% of rated output voltage
+
2mV
2. Max. Load regulation (*6)
-
0.01% of rated output voltage
+
2mV
3. Ripple and noise (p-p,20MHz)
(Following 30 minutes warm-up)
mV
60
60
60
60
60
60
60
80
80
100
150
300
4. Ripple r.m.s.,5Hzto1MHz
(Following 30 minutes warm-up)
mV
8
8
8
8
8
8
8
8
8
10
25
60
5. Temperature coefficient
ppm/°C
100ppm/°C from rated output voltage,following,30 minutes warm-up.
6. Temperature drift
-
0.05% of rated Volt over 8hours interval following 30 minutes warm-up. Constant line, load & temp.
7. Rem. sense compensation/wire
V
1
1
1
1
1.5
2
3
4
5
5
5
5
8. Up-prog.response time,0 to Vomax
(*9)
ms
90
120
150
250
9. Down-prog.response time
Full load
ms
10
50
80
150
250
No load
ms
500
600
700
900
1000
1100
1200
1400
1700
2400
3000
4800
10.Transient response time
ms
Time for the output voltage to recover within 0.5% of its rated output for a load change 10% to 90% of rated output current. Output set-point:10% to 100%
Less than 1m.s, for models up to and including 100V. 2m.s, for models above 100.
11.Hold-up time
ms
More than 200m.s, 100Vac, rated output power.