5
2-8-3. AC Input Wire Connection, 1500W models
1. Strip the outside insulation of the AC cable approx. 10cm. Trim the wires so that the ground wire is 10mmlonger
than the other wires. Strip14mmat the end of each of the wires.
2. Unscrew the base of the strain relief from the helix-shaped body. Insert the base through the outside opening in
the AC input cover and screw the locknut securely
(1.2Nm to 1.6 Nm / 12.7kgf.cm to 16.1kgf
・
cm)
into the base, from
the inside.
3. Slide the helix-shaped body onto the AC cable. Insert the stripped wires through the strain relief base until the
outer cable jacket is flush with the edge of the base. Tighten
(1.8Nm to 2.0 Nm / 18.4kgf to 0.7 kgf
・
cm)
the body to
the base while holding the cable in place. Now the cable is securely fastened inside the strain relief.
Refer to Fig.2-1.
Screw-on locknut
Fig. 2-1: Stripped wires installed in strain relief
4. Route the AC wires to the input connector terminals as required. To connect the wires, loosen the terminal screw,
insert the stripped wire into the terminal and tighten the screw securely
( 0.5Nm to 0.6Nm / 5.1kgf.cm to 6.1kgf
・
cm )
.
5. Route the wires inside the cover to prevent pinching. Fasten the cover to the unit using the M3x8 Flat Head screws
are provided.
◆
Refer to Fig.2-2 for details.
Removable cover
Remove only to inspect AC input
wires connection.
Reinstall cover after inspection.
Assembled Strain Relief
M3×8 Flat Head screws
(2 places)
Fig. 2-2 AC input cover and strain relief, 1500W models
2-8-4. Time to Heat Beforehand
In order to obtain the performance of regulation of this machine, please carry out aging 30 minutes or more.
Summary of Contents for PU100-15
Page 10: ......