TVP4020
Programmers Reference Manual
Graphics Register Reference
191
Name:
X Derivative - Red
Unit:
Color DDA
Region: 0
Offset:
0x0000.8788
Tag:
0x00F1
Reset Value:
Undefined
Read/write
0
8
16
24
31
Integer
Not used
Fraction
Not used
Sign
This register is used to set the X derivative for the Red value for the interior of a trapezoid
when Gouraud shading. The value is 2's complement 9.11 fixed point format.
Name:
Y Derivative Dominant - Red
Unit:
Color DDA
Region: 0
Offset:
0x0000.8790
Tag:
0x00F2
Reset Value:
Undefined
Read/write
0
8
16
24
31
Integer
Not used
Fraction
Not used
Sign
This register is used to set the Y derivative dominant for the Red value along a line, or the
dominant edge of a trapezoid when Gouraud shading. The value is 2's complement 9.11
fixed point format.
dRdx
dRdyDom
Summary of Contents for TVP4020 PERMEDIA 2