ECCN 5E002 TSPA - Technology / Software Publicly Available
CC430F6137, CC430F6135, CC430F6127, CC430F6126, CC430F6125
CC430F5137, CC430F5135, CC430F5133
SLAS554H – MAY 2009 – REVISED SEPTEMBER 2013
www.ti.com
Typical Sensitivity, 315 MHz, Sensitivity Optimized Setting
V
CC
2.0 V
3.0 V
3.6 V
PARAMETER
DATA RATE (kBaud)
UNIT
T
A
-40°C
25°C
85°C
-40°C
25°C
85°C
-40°C
25°C
85°C
1.2
-112
-112
-110
-112
-111
-109
-112
-111
-108
Sensitivity,
38.4
-105
-105
-104
-105
-103
-102
-105
-104
-102
dBm
315MHz
250
-95
-95
-92
-94
-95
-92
-95
-94
-91
Typical Sensitivity, 433 MHz, Sensitivity Optimized Setting
V
CC
2.0 V
3.0 V
3.6 V
PARAMETER
DATA RATE (kBaud)
UNIT
T
A
-40°C
25°C
85°C
-40°C
25°C
85°C
-40°C
25°C
85°C
1.2
-111
-110
-108
-111
-111
-108
-111
-110
-107
Sensitivity,
38.4
-104
-104
-101
-104
-104
-101
-104
-103
-101
dBm
433MHz
250
-93
-94
-91
-93
-93
-90
-93
-93
-90
Typical Sensitivity, 868 MHz, Sensitivity Optimized Setting
V
CC
2.0 V
3.0 V
3.6 V
PARAMETER
DATA RATE (kBaud)
UNIT
T
A
-40°C
25°C
85°C
-40°C
25°C
85°C
-40°C
25°C
85°C
1.2
-109
-109
-107
-109
-109
-106
-109
-108
-106
38.4
-102
-102
-100
-102
-102
-99
-102
-101
-99
Sensitivity,
dBm
868MHz
250
-90
-90
-88
-89
-90
-87
-89
-90
-87
500
-84
-84
-81
-84
-84
-80
-84
-84
-80
Typical Sensitivity, 915 MHz, Sensitivity Optimized Setting
V
CC
2.0 V
3.0 V
3.6 V
PARAMETER
DATA RATE (kBaud)
UNIT
T
A
-40°C
25°C
85°C
-40°C
25°C
85°C
-40°C
25°C
85°C
1.2
-109
-109
-107
-109
-109
-106
-109
-108
-105
38.4
-102
-102
-100
-102
-102
-99
-103
-102
-99
Sensitivity,
dBm
915MHz
250
-92
-92
-89
-92
-92
-88
-92
-92
-88
500
-87
-86
-81
-86
-86
-81
-86
-85
-80
80
Submit Documentation Feedback
Copyright © 2009–2013, Texas Instruments Incorporated
Product Folder Links:
CC430F6137 CC430F6135 CC430F6127 CC430F6126 CC430F6125 CC430F5137
CC430F5135 CC430F5133